Connect The Water Supply - Faber e-MatriX 800 Manuel D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Installation

Connect the Water Supply

The e-MatriX fireplace is equipped with the following
water overflow protections:
• Electromechanical valve in the control
box activated by an overflow sensor in the
water tank.
• Absorption valve activated by an overflow sensor
in the water sump.
To connect the water supply:
1.
Connect all water supply components according
to the diagram shown below. All parts are included
with the product.
2.
Place the water filters at an accessible location
in correct alignment. Follow the "flow" direction
markings on the filters and control box.
!
NOTE: Check all connections for water leakage
before placing the fuel bed and front glass.
A = Mains Water
B = ½ or ¾" Connector
C = ¼" 1m Pipe
D = Ball Valve
1 = Safety Clips (11x)
e-MatriX Engine
E = To be cut from ¼" 1m pipe
F = Mesh Filter
G = In-line Filter
H = Control Box
2 = In-line Filter Brackets (2x)
Check Water Connections for Leaks
1.
Make sure all ball valves are open.
2.
Turn on the water supply.
3.
Press the Main switch [
the ON position.
• If the water level is high enough, the flames will
automatically start after 45 sec.
• If the water level is not high enough the LEDs will
blink twice after 45 sec. Press the Main switch to
the OFF position, wait 5 sec and repeat the step
above. (This process may need to be repeated
several times).
4.
Make sure all water connections are tight and do
not leak.
I = ¼" 1.5m Pipe
J = e-MatriX engine
K = Absorption Valve. User does not need to connect.
Reference for service only.
L = Fill Cap. User does not need to connect.
Reference for service only.
3 = Elbows (4x)
] on the control box to
15

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

E-matrix 650Fef3226l1Fef3226l2lFef3226l2rFef3226l3

Table des Matières