Functional Description - Makita DTM40 Manuel D'instructions

Masquer les pouces Voir aussi pour DTM40:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 11

FUNCTIONAL DESCRIPTION

WARNING:
• Always be sure that the tool is switched off and
battery cartridge is removed before adjusting or
checking function on the tool. Failure to switch off
and remove the battery cartridge may result in serious
personal injury from accidental start-up.
Installing or removing battery cartridge (Fig. 1)
CAUTION:
• Always switch off the tool before installing or removing
of the battery cartridge.
• Hold the tool and the battery cartridge firmly when
installing or removing battery cartridge. Failure to
hold the tool and the battery cartridge firmly may cause
them to slip off your hands and result in damage to the
tool and battery cartridge and a personal injury.
To remove the battery cartridge, slide it from the tool
while sliding the button on the front of the cartridge.
To install the battery cartridge, align the tongue on the
battery cartridge with the groove in the housing and slip it
into place. Insert it all the way until it locks in place with a
little click. If you can see the red indicator on the upper
side of the button, it is not locked completely.
CAUTION:
• Always install the battery cartridge fully until the red
indicator cannot be seen. If not, it may accidentally fall
out of the tool, causing injury to you or someone
around you.
• Do not install the battery cartridge forcibly. If the car-
tridge does not slide in easily, it is not being inserted
correctly.
Battery protection system (Lithium-ion battery
with star marking) (Fig. 2)
Lithium-ion batteries with a star marking are equipped
with a protection system. This system automatically cuts
off power to the tool to extend battery life.
The tool will automatically stop during operation if the
tool and/or battery are placed under one of the following
conditions:
• Overloaded:
The tool is operated in a manner that causes it to draw
an abnormally high current.
In this situation, slide the slide switch on the tool toward
the "O (OFF)" position and stop the application that
caused the tool to become overloaded. Then slide the
slide switch toward the "I (ON)" position again to
restart.
If the tool does not start, the battery is overheated. In
this situation, let the battery cool before sliding the slide
switch toward the "I (ON)" position again.
• Low battery voltage:
The remaining battery capacity is too low and the tool
will not operate. In this situation, remove and recharge
the battery.
Indicating the remaining battery capacity (Fig. 3)
(Only for battery cartridges with "B" at the end of the
model number.)
Press the check button on the battery cartridge to indi-
cate the remaining battery capacity. The indicator lamps
light up for few seconds.
Indicator lamps
Lighted
Off
015658
NOTE:
• Depending on the conditions of use and the ambient
temperature, the indication may differ slightly from the
actual capacity.
Switch action (Fig. 4)
CAUTION:
• Before installing the battery cartridge into the tool,
always check to see that the tool is switched off.
To start the tool, slide the slide switch toward the "I (ON)"
position.
To stop the tool, slide the slide switch toward the
"O (OFF)" position.
Adjusting the orbital stroke rate (Fig. 5)
The orbital stroke rate is adjustable. To change the orbital
stroke rate, turn the dial between 1 and 6. The higher the
number is, the higher the orbital stroke rate is. Preset the
dial to the number suitable for your workpiece.
NOTE:
• The dial cannot be turned directly from 1 to 6 or from 6
to 1. Forcing the dial may damage the tool. When
changing the dial direction, always turn the dial moving
it through each intermediate number.
Remaining
Capacity
Blinking
75% to 100%
50% to 75%
25% to 50%
0% to 25%
Charge the
battery.
The battery may
have
malfunctioned.
7

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Dtm50

Table des Matières