Antari F-4 Fazer Mode D'emploi page 7

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

DMX Operation
Making the DMX Connection – Connect the machine to a DMX controller or to one of the
machines in the DMX chain. The machine uses a 3-pin or 5-pin XLR connector for DMX
connection, the connector is located on the front of the machine.
Address Setup – Use control menu to set DMX address. The machine occupies 2 control
channels. The starting address is defined as the first channel from which the machine will
respond to the controller. Always double check to make sure there are no overlapping
channles in order to control the machine correctly.
DMX Channel Function
Channel 1
Faze Output Level
Channel 2
Fan Output Level
Fluid
Only use Antari FLG water-based liquid for the F-4 Fazer. The machine is tested and
calibrated with this liquid to get the best output performance. Warranty will be voided if any
other type of liquid is used, improper use of liquid may lead to machine failure or
Pin
1
2
3
4
5
DMX Value Range
0 – 5
6 – 255
DMX Value Range
0 – 5
6 – 255
Function
Ground
Data-
Data+
N/A
N/A
Function
Faze Off
Faze Output 1 – 100%
Function
Fan 20%
Fan 21 – 100%
7