10. MALFUNCTION AND TROUBLESHOOTING
Make sure that the vacuum cleaner is always switched off and disconnected from the mains for repair.
Malfunctions are not always due to defects in the vacuum cleaner.
Malfunction
Decrease in vacuuming power
Vacuum cleaner does not start
Vacuum cleaner does not start when the
tool is switched on in "Auto" mode
Disposal bag is vacuumed onto the filter
cartridge
Dust class M vacuum cleaner: with filter
bag inserted, dust in the container
Dust class M vacuum cleaner:
Warning device constantly active.
ORIGINAL ACCESSORIES
11.
Article designation
Filter cartridge
Fleece filter bags (packing unit = 5 pcs.) HEPA 13
Disposal bag
Further accessories can be found in the spare parts drawing.
These are available on request from the SPRiNTUS sales
team, on the Internet: https://shop.sprintus.eu/, e-mail:
kontakt@sprintus.eu or via the QR code on the next page.
16 I
Cause
Filter cartridge dirty
Filter bag full
Container full
Nozzle, pipes or hose clogged
Container nozzle / filter bag flange clogged
Mains plug not plugged in
No mains power
Connection cable defective
Water sensor switched off
Vacuum cleaner switched to "Auto"
Power tool not plugged into socket on vacuum
cleaner
Tool does not reach the minimum power of 20 W to be
recognised by the vacuum cleaner.
Disposal bag is not inserted and fitted correctly.
Filter bag not fitted correctly.
Filter cartridge clogged
vacuum hose blocked
Container full
Wrong hose diameter selected
Special features Item no.
HEPA 13
118.100
102.031
118.138
Remedial action
Close the vacuum connection with the sealing
plug and switch on the vacuum cleaner again
and wait for the cleaning cycle to clean the filter
cartridge.
Change
Empty
Clean
Clean
Plug in the mains plug
Check fuse
Renew
Empty container and clean electrodes
see "5. Switching on the vacuum cleaner"
Insert the mains plug into the socket on the
vacuum cleaner
Use the vacuum cleaner in continuous operation
Place the disposal bag completely over the edge
of the container and press the flange completely
over the receptacle and put the holes provided
over the electrodes of the water shut-off.
Press the filter bag completely over the filter bag
flange.
Close the vacuum connection with the sealing
plug and switch on the vacuum cleaner again
and wait for the cleaning cycle to clean the filter
cartridge.
Remove vacuumed material from hose
Empty container
Set the correct hose diameter.