Ugolini QUICK-GEL Carnet D'instructions page 20

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

figure 22)
figure 22
8 Remove the tap assembly and disassemble it, following the
sequence specified. (see figure 23)
figure 23
9 Remove the scraper. (see figure 24)
figure 24
10 Remove the coupling with seal. (see figure 25)
figure 25
11 Remove the drip tray from its seat. (see figure 26)
5. 4. 2 WASHING
IMPORTANT
If the power supply cable is damaged, it must be replaced
by the manufacturer or by its service centre, or in any
case by similar qualified professionals, in order to avoid
all risk.
ATTENTION
Before performing any cleaning, always disconnect the
dispenser from the electricity supply by unplugging it or
turning off the external wall switch.
1
Fill a basin with approximately one gallon of hot water (45-
60°C) and 1 oz of specific detergent equipped (stera sheen
green
label); indeed, a solution that is too concentrated may
damage the parts to be washed, whereas one that is too diluted
may not clean properly. Do not use any abrasive detergents.
IMPORTANT
In order to avoid damaging the dispenser, only use deter-
gents that are compatible with plastic components.
2 In order to avoid damaging the dispenser, only use
detergents that are compatible with plastic components.
ATTENTION
When cleaning the dispenser, do not use large quantities
of water in the vicinity of electrical components; if you
do, this may cause electric shocks or damage the
dispenser.
3 Wash the evaporator cylinder, the upper tank and the
connecting pipe using the brush supplied with the unit.
4 Rinse all washed parts under running water.
5. 4. 3 SANITIZING
Sanitising must be performed immediately prior to
20
figure 26

Publicité

Table des Matières
loading

Table des Matières