Routing the exhaust air through
a wall box into a fireplace or ventila-
tion shaft
In the case of a connection to a venti
lation shaft insulated against moisture,
the responsible chimney sweep is to be
informed and the approval of the local
building depart ment or the owner of
the building must be obtained.
At all events, have the safe operation
►
confirmed by your chimney sweep.
Warning
Danger of suffocation!
If additional appliances are operated
in the room where the appliance is
installed or in adjoining rooms, such as
gasfired heating systems, gasfired
instantaneous water heaters, coal
fired ovens with a chimney connection
or open fireplaces, a partial vacuum
may be caused leading to the sucking
back of the exhaust gases.
Do not route the exhaust pipe into a
►
fireplace that is connected to devices
such as gas or coal fired stoves and
ovens, or gas room heaters.
Ablaufmöglichkeit für Kondenswas-
ser
At the lowest point in the exhaust air
duct, you are recommended to fit a
«condensation water collector» (pro
prietary) or a condensation dis charge
hole of about ø = 3 mm.
46 EN
Electrical connection
Notice
Connection of the appliance to the
power supply must be carried out by a
specialised electrician.
Perform the electrical connection
according to the regulations or pro
visions made by the local electricity
authority and utility companies.
Approval for fixed connection, allpole
disconnectable by a main switch with
contact distance of min. 3 mm or plug
contact.
Reduced mains power
The appliance may be changedover to
a reduced connection rate.
Notice
The switchover must be carried out by
a specialist elec tri cian.
For lower connected loads, the setting
►
Reduced mains power needs to be
adjusted accordingly.
Mains cable
The appliance will be delivered with a
5wire mains cable (length: 150 cm)
for connection to 3phase alternating
current with neutral conductor.
Fuses and switches are not included in
the scope of supply.