Ultraflex UP 20 F Manuel D'installation Et D'entretien page 12

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

ULTRAFLEX
4
By using the proper template supplied with
this manual, make the 3 holes (4) for the 3
dowels and the central hole (5).
5 Position the pump (2) on the dashboard front
side (6) interposing the gasket (7) and fix it by
inserting the 3 washers (8) and by tightening
the 3 self-locking nuts (9) with a 10 mm wrench
and a torque of 8 Nm (5,90 lb ft).
CAUTION
If the self-locking nuts are disassembled (9), they
must be replaced. (Contact our assistance
service, see page 6).
WARNING
Install the pump by positioning the filling hole
(10) towards the top (see the picture) for the right
pump operation and to allow filling and purging
the system completely (see par. 3.7).
6
Position the steering wheel supplied
separately (11) on the pump shaft (12) by using
the suitable key (13). Insert the washer (14) and
tighten the self-locking nut (15) with a 19" open
end wrench and with a torque of 30 Nm (22,14
lb ft); then grease the thread by using some anti-
seize grease MOLYKOTE
one.
CAUTION
If the self-locking nut (15) is disassembled, it must
be replaced. (Contact our assistance service, see
page 6).
page 12
of 71 -
PUMP FOR HYDRAULIC SYSTEMS
®
1000 or a similar
Installation and maintenance manual
4
6
10
2
13
11
14
15
5
8
9
8
9
9
8
7
12

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Up 20 t

Table des Matières