Ordinary Maintenance; Steering Wheel Disassembly; Troubleshooting - Ultraflex UP 20 F Manuel D'installation Et D'entretien

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

ULTRAFLEX
5 MAINTENANCE

5.1 Ordinary maintenance

WARNING
Poor installation and maintenance may result in loss of steering and cause property damage and/or perso-
nal injury. Maintenance requirements change according to climate, frequency and the use. Inspections are
necessary at least every year and must be carried out by specialized marine mechanics. Check the cylinder
fittings and the seals and the helm gaskets to prevent leaks. Replace them if necessary.
To keep a suitable oil level in the tank, fill and bleed the system as described in this manual in paragraph
3.9 and in the bleeding procedure of ULTRAFLEX cylinders. Check the hose and the entire system wear, the
nut and bolt tightening every six months and make sure that they are not damaged. Clean the system using
water and non-abrasive soap. .
DANGER
Use only compatible hydraulic oils, indicated in the paragraph "technical features" and "filling and purging".
Do not use brake oils or automatic transmission fluid (ATF) in any case.

5.2 Steering wheel disassembly

To remove the steering wheel from the pump shaft, use a suitable extractor.
WARNING
Do not use a hammer or other tools that could seriously damage the pump.

5.3 Troubleshooting

WARNING
Whenever the following checks need the removal and/or disassembly of the steering system components,
such work must be carried by specialized staff. ULTRAFLEX offers general information only and is not
responsible for any consequences resulting from incorrect disassembly.
PROBLEM
During the filling, the
steering system becomes
completely jammed.
The system is very difficult
to fill.
Air keeps bubbling at the
top of the steering system
tank even after filling the
system completely.
CAUSE
• Blockage in the hoses between
steering system and cylinder.
• Air in the system.
• Leaks from the cylinder
bleeder.
• Coiled hose.
• Helm has been mounted upside
down.
PUMP FOR HYDRAULIC SYSTEMS
Installation and maintenance manual
SOLUTION
• Replace hoses.
DANGER
The damaged hose must be replaced,
otherwise it may cause loss of steering
and severe personal injury or property
damage.
• Repeat the filling and the bleeding
procedure of the system.
• Install horizontally the hoses and in
any case with a maximum inclination
of 3cm each meter.
• Tighten the bleeder on the cylinder.
• Uncoil and straighten the hose.
• Mount the helm with the filling hole in
up position.
page 21
-
of 71

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Up 20 t

Table des Matières