Maintenance
4.8
53M indoor unit error codes
Error code
E0/EA
Indoor unit EEPROM parameter error
Communication error between the indoor unit and the outdoor
E1
unit
E3
Internal fan speed outside the normal range
Indoor room temperature sensor T1 circuit open or in short
E4
circuit
T2 evaporator coil temperature sensor circuit open or in short
E5
circuit
EC
Detection of refrigerant leaks (for some models)
EE
Water level alarm malfunction
F0
Current overload protection
Outdoor room temperature sensor T4 circuit open or in short
F1
circuit
T3 condenser coil temperature sensor circuit open or in short
F2
circuit
TP compressor drain temperature sensor circuit open or in short
F3
circuit
F4
Outdoor unit EEPROM parameter error
F5
External fan speed outside the normal range (for some models)
Communication error between two internal chips
FA
(for some models)
P0
IPM malfunction or IGBT overcurrent protection
P1
Over-voltage/under-voltage protection
P4
Compressor inverter drive error
P5
Indoor unit mode conflict (combination with MULTI outdoor unit)
P6
Low pressure protection (for some models)
P7
IPM module high temperature protection (for some models)
Cause
"Operation
Timer light
light (flashes)"
OFF
Once
OFF
Twice
OFF
4 times
OFF
5 times
OFF
6 times
OFF
7 times
OFF
8 times
ON
Once
ON
Twice
ON
3 times
ON
4 times
ON
5 times
ON
6 times
ON
11 times
FLASHING
Once
FLASHING
Twice
FLASHING
5 times
FLASHING
6 times
FLASHING
7 times
FLASHING
8 times
31