Led L5 (Yellow); Module States (Modes) - Tyco TL8803GI Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

The module is in PowerSave mode
l
The module just powered up
l
There is no HSPA coverage in the area. Alarm.com recommends a steady signal level of 2 or higher for
l
proper operation of the module
Note: In Connected Mode, the LED toggles on and off.

LED L5 (yellow)

LED L5 indicates Z-Wave state and errors. See the table below for more information.
Number of flashes
1
2
3
4
5
6
7
8
There are four module states, or modes, as described in the following table:
Mode
AC power is correct and the module is not currently talking to Alarm.com.
L1 - Flashes general or cellular errors, if any
L2 – Flashes Ethernet errors, if any; Communication with panel
Idle
L3 - Communication with radio unit
L4 - Signal level (0 to 5 bars)
L5 - Flashes Z-Wave state or errors, if any
The module just powered up, AC power is down, or AC power is recently restored and the battery is
recharging. The module is fully functional and goes into Connected mode as soon as a signal needs to be
sent. Press and hold the 5 Key for 2 seconds to switch the module into Idle mode and update the signal
level reading. The system goes into Idle mode every 2 hours to check for any incoming messages.
PowerSave
L1 - Inactive
L2 - Communication with panel
L3 - Same flashing pattern as L2
L4 - Inactive
L5 - Inactive
The module is currently talking to Alarm.com. The module stays in Connected mode for at least four
minutes after reporting an event to Alarm.com, unless the 5 Key is pressed and held for 10 seconds,
which causes the module to go back to Idle mode.
L1 - Flashes general or cellular errors, if any
Connected
L2 - Flashes Ethernet errors, if any; Communication with panel
L3 - Communication with Alarm.com
L4 - Alternates two seconds on, and then two seconds off
L5 - Flashes Z-Wave state or errors, if any
The panel is not connected to AC power, or there is an AC power failure, and the battery level is low. The
Sleep
module connects to Alarm.com to send a signal, but otherwise draws almost no power.
Note: If the TL8803GI module is powered down for a short period of time, buffered messages from Alarm.-
com can be received when module power is restored.
Successfully added/removed node (last 60 seconds)
Delete Mode
Add node attempt failed (last 60 seconds) because device already in network
Add Mode
Replicate Mode
Learn Mode Error (lasts 60 seconds)
No Node Info
No other nodes are in the network

Module states (modes)

Device status or error
Description
- 18 -
Troubleshooting

Publicité

Table des Matières
loading