Tyco TL8803GI Mode D'emploi page 14

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Section
019
024
Swinger Shutdown
377
377
Communication Delay
Wireless Device Low
377
Battery Transmission
380
380
380
382
804 [sensor #]
Clock
The TL8803GI module sets the panel clock when it connects to Alarm.com and then updates it every 18 hours.
It is important to select the correct panel time zone on the Alarm.com website, or the panel time will not be
accurate. If a system is powered up before the customer account has been created, the time zone will default
to Eastern Standard Time.
Option
6
5
(Maintenance)
AC Failure
Random value between
Delay
1
2
5
6
003
Five minute delay [07]
Value
Set according to
dealer's Alarm.com
setting
OFF
010
001 and 030
001
ON
OFF
OFF
OFF
- 14 -
Description
Enables Duress Code changes from
Alarm.com.
Realtime clock must be disabled to ensure
panel time is accurate.
Swinger Shutdown for maintenance signals
should be set to 010 to ensure trouble
notifications can be sent.
AC Failure Communication Delay should be
set between 001 and 030 to ensure
notifications for power failures are received.
Wireless Device Low Battery Transmission
Delay should be set to 001 to ensure
notifications for low batteries are received.
Communications must be enabled for the
module to communicate with the panel.
System should transmit alarm restores
immediately when the zone is restored.
The redundant communications method must
be set as backup.
AC Failure Transmission Delay must be in
minutes.
High Traffic Shutdown must be set to five
minutes for devices being used with
Alarm.com's Activity Monitoring.
Note: This feature can reduce the battery life
of wireless PIR sensors. In order to avoid this,
hardwired PIR sensors can be used instead.
Installation

Publicité

Table des Matières
loading

Table des Matières