8.

Storage

All parts of a Clean-air system must be stored in
environment with temperature range 0-40°C and
humidity range 20-80% Rh. The storage life is 2
years for the product if stored in original unopened
package.
9.

Warranty

There is a 12 month warranty covering production
defects , a 6 month warranty for batteries.
Warranty begins from the date of purchase. The
claim must be lodged at the dealer's place. The
invoice or receipt must be declared if claiming the
warranty.

10. Technical data

CA BASIC 2000
Airflow
Weight of the blower unit incl. the
filter and battery
Noisiness
NiMh battery lifetime
One charging cycle
Belt size
Recommended temperature range
Recommended humidity range
Certification
Expected operating time of the blower unit
after being fully charged (hours)
CA BASIC DUAL FLOW
CA BASIC FLOW CONTROL
CA CHEMICAL
Airflow
Weight of the blower unit incl. the
filter and battery
Noisiness
NiMh battery lifetime
One charging cycle
Belt size
Recommended temperature range
Recommended humidity range
Certification
__________________________________________________________________________________
NOTE: Batteries get discharged even if not in use.
Therefore in case of a long-term storage it is fully
recommended to charge the NiMH batteries every
12 months.
The claiming procedure will be successful only on
condition that there were no changes made on the
blower unit incl. the battery and charger.
If the damage is caused by not changing a clogged
filter in good time or using a filter which has been
cleaned by the customer, the claim will not be
proceeded.
CAB DUAL FLOW
160* - 140 l/min
200* - 180 l/min
* with fully charged attery and clean filters
900 g
55 - 61 dB
500 to 700 charging cycles
10 to 14 hours
80 to 100 cm
10°to 40°C
20 to 80 % Rh
EN 12 941 TH1
Airflow
middle
max
middle
X
X
X
X
X
CACH DUAL FLOW
140* a 200* l/min
* with fully charged attery and clean filters
1 050 g
55 to 61 dB
500 to 700 charging cycles
10 to 14 hours
75 to 130 cm
10°to 40°C
20 to 80 % Rh
EN 12 941 TH1
EN 12 942 TM3
8
7
CAB FLOW CONTROL
140 to 210 l/min
(at 8 adjustable flow rates)
EN 12 941 TH2/TH3
Filter
PSL
NOTE! operating time can be
shortened in case of clogged filter
11-12 h
or undercharged battery
6 h
10 h
6-7 h
4-5 h
CACH FLOW CONTROL
60, 80, 100 l/min – mask mode
120,140,160 l/min – hood mode
1 150 g
EN 12 941 TH2/TH3
EN 12 942 TM3