Fault
The unit does not work at all
The unit does not supply satisfactory
amount of air.(low air-flow)
The unit works only for a short time.
It is impossible to charge the batte-
ry..
It is impossible to charge the battery
sufficiently.
8.

Storage

All parts of the CleanAIR system must be stored at
temperatures between 0° C and 40°C with relative
air humidity inbetween 20 and 80 % Rh. Maximum
storage life in undamaged wrapping is 2 years
excluding batteries!
During storage self-discharge of batteries occurs.
Batteries stored for long terms must be fully char-
ged every 6 months.
9.

Warranty

The Quality Warranty ensures you will receive a
replacement if a product presents any manufactu

10. Technical data

CA CHEMICAL 2F
Minimum air-flow
Display
Weight of unit including battery
Unit noise
Battery life time
One recharging cycle
Belt size
Advised temperature range for work
Advised air humidity range for work
Certification
______________________________________________________________________________
Probable cause
Battery discharge
(check : the unit starts working after
replacing the battery with another
functional battery)
Fault of motor, electronics or char-
ging connector
Blocked air-hose or air channel.
Air leakage.
The battery is not charged enough.
Clogged filter.
Clogged filter.
The battery is not charged enough .
Fault of charger.
Bad battery connector .
Termination of battery life time.
ring or material defects within 12 months from the
date of purchase. For batteries it is 6 months from
the date of purchase. The warranty claim must be
lodged at sales organization. At the same time the
proof of purchase must be handed in ( invoice or
certificate of delivery).
The warranty can be acknowledged only if no inter-
ventions into the powered respiratory unit and char-
ger have been made. The warranty does not cover
defects caused by the late replacement of the filter
or by using a filter which was damaged by cleaning
or by filter blow-through.
160 - 210 l/min eligibly in 5 rates
TFT display
1000 g
55 to 61 dB
Max.500 recharging cycles
3 - 4 hours
75 to 130 cm at waistline
0° to 40°C
20 to 80 % Rh
EN 12 941/A2 TH2/TH3 ; EN 12 942/A2 TM3
7
Recommendation
Recharge the battery.
(if the problem outlasts, check the battery)
Return to the producer for repairing.
Check and remove the possible block.
Check all sealing elements and joints,
make sure the hose is not damaged and
without leakage.
Charge the battery.
(if the problem outlasts, check the batte-
ry)Replace the filter.
Replace the filter.
Charge the battery.
(if the problem outlasts, check the battery)
Contact your supplier.
Check the battery contact.
Install a new charged battery.