Fault
The unit does not work at all
The unit does not supply satisfactory
amount of air.(low air-flow)
The unit works only for a short time.
It is impossible to charge the battery..
It is impossible to charge the battery
sufficiently.
8.

Storage

All parts of the CleanAIR system must be stored at
temperatures between 0°C and 40°C with relative air
humidity inbetween 20 and 80 % Rh. Maximum storage
life in undamaged wrapping is 2 years
excluding batteries!
During storage self-discharge of batteries occurs.
Batteries stored for long terms must be fully charged
every 6 months.
CA CHEMICAL 2F
Minimum air-flow
Display
Weight of unit including battery
Unit noise
Battery life time
One recharging cycle
Belt size
Advised temperature range for work
Advised air humidity range for work
Certification
Probable cause
Battery discharge
(check : the unit starts working
after replacing the battery with
another functional battery)
Fault of motor, electronics or
charging connector
Blocked air-hose or air channel.
Air leakage.
The battery is not charged
enough.
Clogged filter.
Clogged filter.
The battery is not charged
enough .
Fault of charger.
Bad battery connector .
Termination of battery life time.
9.
The Quality Warranty ensures you will receive a repla-
cement if a product presents any manufacturing or
material defects within 12 months from the date of
purchase. For batteries it is 6 months from the date of
purchase. The warranty claim must be lodged at sales
organization. At the same time the proof of purchase
must be handed in ( invoice or certificate of delivery).
The warranty can be acknowledged only if no inter-
-ventions into the powered respiratory unit and char-
-ger have been made. The warranty does not cover
defects caused by the late replacement of the filter or
by using a filter which was damaged by cleaning or by
filter blow-through.
2F Plus
120 - 235 l/min eligibly in 5 rates
TFT display
960 g
55 to 61 dB
Max.500 recharging cycles
3 - 4 hours
75 to 130 cm at waistline
0°to 40°C
20 to 80 % Rh
EN 12 941/A2 TH2/TH3 ; EN 12 942/A2 TM3
8
Recommendation
Recharge the battery.
(if the problem outlasts, check the
battery)
Return to the producer for repairing.
Check and remove the possible block.
Check all sealing elements and joints, make
sure the hose is not damaged and without
leakage.
Charge the battery.
(if the problem outlasts, check the battery)
Replace the filter.
Replace the filter.
Charge the battery.
(if the problem outlasts, check the
battery)
Contact your supplier.
Check the battery contact.
Install a new charged battery.

Warranty