Testing the installation
Place the locomotive on the programming track (without its housing) and read the address. The
decoder is programmed ex-works to the address 03. If you have connected the decoder correctly
thus far, you should now be able to read the address. If you are not able to do so, it is possible that
you have made a mistake when connecting the cables. Do not subject the locomotive to full running
track power until you obtain the correct "03" address read-out. Check the cable connections and
change them as required. You should now be able to send your locomotive on its first test run on
your layout.
5
Features of the STANDARD decoder
The following contains a short survey of the features of the STANDARD decoder as well as
information on how to set them.
You can find detailed information on the features and their settings in the "Manual Plus
Decoders" that you can download from the Lenz Elektronik GmbH website www.lenz-
elektronik.de
5.1 Capacity and protection equipment
The motor output has a current-carrying capacity of up to 1 A even without special installation on
cooling surfaces! The function outputs have current-carrying capacities of 100mA each.
The decoder is protected against overloading, short circuits and overheating. In case of a fault, the
corresponding bit is set in CV30 which will state the type of fault which has occured. This bit can be
deleted via programming.