Operation Instructions for Versati III
2
Quantity of segments
Temperature of the first
3
segment
4
Duration of each segment
Temperature difference of
5
each segment
3. When this setting is finished, by pressing "Start" this setting will be saved and start working, and by pressing
"Stop" the function will halt.
[Notes]
● This function can be activated only when the unit is turned off. When it is done with the unit keeping "On", a
window will pop up, saying "Please turn off the system first!".
●When this function has been activated, "On/Off" operation will be deactivated. By pressing On/Off , a window
will pop up, saying "Please disable the floor debug!".
●When "Floor debug" has been activated; "Weekly timer", "Clock Timer", "Temp timer" and "Preset mode"
will be deactivated.
● "Emergen. mode", Disinfection", "Holiday mode", "Manual defrost", "Forced mode" and "Refri. recovery"
cannot be activated at the same time with "Floor debug". If doing so, a window will pop up, saying "Please disable
the floor debug!".
●Upon power failure, "Floor debug" will back to "Off" and the runtime will be zeroed.
●When "Floor debug" has been activated, "T-floor debug" and "Debug time" can be viewed.
●When "Floor debug" has been activated and works normally; the corresponding icon will be displayed at the
upper side of the menu page.
●Before activating "Floor debug", make sure "Segment time" of each segment is not zero. If so, a window will
pop up, saying "Segment time wrong!" In this case, "Floor debug" is allowed to be activated only when "Segment
time" has changed.

2.4.11 Manual Defrost

[Operation Instructions]
At the commissioning parameter setting page, by touching "Manual defrost ", the control panel will access to
the corresponding setting page.
[Notes]
●This setting will not be memorized upon power failure.
●This setting can be set only when the unit has turned off. When this function has been activated, ON operation
is un-allowed.
● Defrosting will quit when the defrosting temperature goes to 20
minutes.
2.4.12 Force Mode
[Operation Instructions]
1. At the commissioning parameter setting page, by touching "Force mode", the control panel will access to the
corresponding setting page.
2. At the "Force mode" setting page, it can be set to "Force-cool", 'Force-heat", and "Off". When it is set to
"Force-cool" or "Force-heat", the control panel will directly go back to the homepage and response to any touching
operation except the ON/OFF operation, with a window popping up, saying "The force-mode is running!". In this
case, by touching ON/OFF, "Force mode" will quit.
[Notes]
●This function is allowed only when the unit has just repowered and not turned on. For the unit which once has
been put into operation, this function is unavailable, alerting "Wrong operation!".
● It will not be memorized upon power failure.
Segments
1~10
25~35℃ /
Period 1 temp
77~95°F
Segment time
12~72 hours
2~10℃ /
ΔT of segment
36~50°F
21
1
25℃ /
77°F
0
5℃ /
41°F
or the defrosting duration is equal to 10
1
1℃
12 hours
1℃