Electrical Requirements
Use ONLY wire size recommended for
Wire Size
single outlet branch circuit.
Use ONLY type and size fuse or HACR
circuit breaker indicated on unit's rating
plate (See sample below). Proper over
current protection to the units is the respon-
sibility of the owner.
Unit MUST be grounded from branch circuit
to unit, or through separate ground wire
provided on permanently connected units.
Be sure that branch circuit or general
purpose outlet is grounded.
Use recommended wire size given in tables
and install a single branch circuit. All wiring
must comply with local and national codes.
NOTE: Use copper conductors only.
NOTE: All field wiring must comply with NEC and local
codes. It is the responsibility of the installer to insure that
the electrical codes are met.
Electrical Rating Tables
NOTE: Use copper conductors ONLY. Wire sizes are per
NEC. Check local codes for overseas applications.
Recommended branch circuit wire sizes
Nameplate Maximum Circuit
Breaker Size
20A
30A
40A
55A
70A
AWG --- American Wire Gauge
*
Single circuit from main box.
** Based on 100' or less of copper, single insulated conductor at 60° C
THINK
Do not remove, disable or
bypass this unit's
SAFETY
safety devices. Doing
FIRST
so may cause, fire, injuries
or death.
AWG Wire Size
12
10
8
6
4
AVERTISSEMENT
WARNING
Ne pas supprimer, désactiver ou
contourner cette l'unité
des dispositifs de sécurité. faire
vous risqueriez de provoquer,
le feu, les blessures
ou la mort.
* Single circuit from main box. Based on copper
wire 100' or less, single insulated conductor at
60º C.
NOTE: Use copper conductors ONLY. Wire sizes
are per NEC. Check local codes for overseas
applications.
Sample Nameplate
WARNING
Electrical shock hazard.
Turn OFF electric power before service or
installation.
Unit must be properly grounded.
Unit must have correct fuse or circuit breaker
protection.
Unit's supply circuit must have the correct
wire conductor size.
All electrical connections and wiring must be
installed by a qualified electrician and
conform to the National Electrical Code and all
local codes which have jurisdiction.
Failure to do so can result in property
damage, personal injury and /or death.
ADVERTENCIA
No eliminar, desactivar o
pasar por alto los dispositivos
de seguridad de la unidad. Si lo
hace podría producirse fuego,
lesiones o muerte.
120524
COOLING EQUIPMENT
FOLLOWING ITEMS
OUTDOOR GRILLE
INDOOR GRILLE
3