Operation; Warning - Protemp PT-80-OFR Manuel De L'utilisateur Et Mode D'emploi

Chaufferette au kérosène
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Fueling The Heater:
Kerosene
For optimal performance of this heater, it is strongly
suggested that Kerosene be used. Kerosene has been
refined to virtually eliminate contaminants, such as
sulfur, which can cause a rotten egg odor during the
operation of the heater. Using diesel fuel can cause
excess soot production. Do not use Bio-Diesel as this
fuel will damage your heater's seals and filter.
- CSA certified for use with K-1 kerosene, no. 1 & no. 2 diesel,
JP8/Jet A Fuel, no. 1 and no. 2 fuel oil.
DANGER
OR OPERATING. FIRE OR EXPLOSION COULD
RESULT.
CAUTION
FILL THE TANK OUTDOORS. BE SURE THAT
THE HEATER IS ON LEVEL GROUND WHEN FU-
ELING, AND NEVER OVERFILL THE TANK.

WARNING

- NEVER use fuel such as, benzene, alcohol, white gas,
camp stove fuel, farm diesel, paint thinners, or other oil
compounds in this heater. THESE ARE VOLATILE
FUELS THAT CAN CAUSE A FIRE OR EXPLOSION.
- NEVER store Kerosene in the living space. Kerosene
should be stored in a well ventilated area outside the
living area.
- NEVER store Kerosene in direct sunlight or near a source
of heat.
© 2019 Pinnacle Climate Technologies, Inc.
NEVER LEAVE HEATER UNATTENDED WHILE BURNING
®

OPERATION

NEVER REFUEL
THIS HEATER
WHILE IT IS HOT
NEVER FILL THE
FUEL TANK IN-
DOORS. ALWAYS
DO NOT USE GASO-
LINE OR CRANK-
CASE DRAININGS.
OR WHILE CONNECTED TO A POWER SOURCE
- NEVER use Kerosene that has been stored from one
season to the next. Kerosene deteriorates over time.
OLD Kerosene WILL NOT BURN PROPERLY IN THIS
HEATER.
NOTE: Kerosene should only be stored in a blue
container that is clearly marked "Kerosene." Never
store Kerosene in a red container. Red is associated
with gasoline.
DANGER
Ventilation:
- Risk of indoor air pollution and Carbon Monoxide
Poisoning. Use heater only in well ventilated areas.
- Refer to Safety Information on pages 2-3 for information
about Carbon Monoxide Poisoning.
- ALWAYS provide a fresh air opening in the heated space
of at least 2,800 square centimeters (3 sq. ft) for each
100,00 Btu/Hr. (29 kW) of heater output. Provide a
larger opening if more heaters are being used.
Minimum Ventilation Opening Needed
80-OFR
2.4 ft.
2230 cm
7
Kerosene Radiant Heater User's Manual
CARBON MONOXIDE
POISONING MAY
LEAD TO DEATH!
125-OFR-A
3.75 ft.
2
3484 cm
2
2
2