Liquid Propane Cylinder Requirements; Connecting The Liquid Propane Cylinder - Nexgrill 720-0697E Mode D'emploi

Masquer les pouces Voir aussi pour 720-0697E:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

The installation of this appliance must conform with local codes or, in the absence of local codes, with
either the National Fuel Gas Code, ANSI Z223.1/NFPA 54, National Gas Propane Installation Code, CSA
B149.2.
Installation in Canada must be in accordance with the Standard CAN/CGA-B149.2 (installation code for
gas burning appliances and equipment) and local codes.

LIQUID PROPANE CYLINDER REQUIREMENTS

(20-lb. Cylinder)
A dented or rusty Liquid Propane Cylinder may be hazardous and should be checked by your supplier.
Never use a cylinder with a damaged valve. The Liquid Propane Cylinder must be constructed and
marked in accordance with the specifications for Liquid Propane Cylinders by the United States
Department of Transportation (DOT) or the National Standard of Canada, CAN/CSA-B339, Cylinders,
Spheres and Tubes for Transportation of Dangerous Goods Commission.
The 20-lb. Cylinder must have a shut off valve terminating in a valve outlet specified, as applicable, for
connection type QCC1 in the standard for compressed gas cylinder valve outlet and inlet connection
ANSI/CGA-V-1.
Storage of an outdoor cooking gas appliance indoor is permissible only if the cylinder is disconnected and
removed from the outdoor cooking gas appliance. The Cylinder system must be arranged for vapor
withdrawal. The cylinder must include a collar to protect the Cylinder valve.
Manifold pressure: (operating) 11 inches water column (W.C.), (non-operating) 11.2 inches water column
(W.C.).
Liquid Propane Cylinders must be provided with a listed overfilling prevention device.
Remove the plastic valve cover from the Liquid Propane Cylinder. Make sure the grill gas hoses do not
contact the grease pan or grill firebox when the Liquid Propane Cylinder is placed into the cart.

CONNECTING THE LIQUID PROPANE CYLINDER

To connect the Liquid Propane Gas Supply Cylinder:
a) The cylinder valve should be in the "OFF" position. If not, turn the valve
clockwise until it stops.
b) Make sure the cylinder valve has the proper type-1 external male thread
connections per ANSI Z21.81.
c) Make sure the burner valves are in the "OFF" position.
d) Inspect the valve connections, port and regulator assembly. Remove debris and inspect the hose
for damage.
e) When connecting the regulator assembly to the valve, use your hand to tighten the nut clockwise
until it stops. Use of a wrench could damage the quick coupling nut and result in a hazardous
situation.
f)
Open the cylinder valve fully by turning the valve counterclockwise.
g) Before lighting the grill, use a soap and water solution to check all the connections for leaks.
h) If a leak is found, turn the cylinder valve "OFF" and do not use the grill until a local Liquid Propane
dealer can make repairs.
18

Publicité

Table des Matières
loading

Table des Matières