UNIT SCOPE
The air conditioners from the integrated
system of the FW-R series are autono-
mous units designed and manufactured to
maintain the best ambient conditions.
With sombre and elegant lines, they are
particularly quiet that makes them suit-
able to be installed in domestic or com-
mercial ambients.
They are supplied with a water cooled con-
densing unit and besides carrying out the
typical functions of cooling, dehumidi-
fication, ventilation and filtration of the
air, present notable advantages from the
point of view of installation and applica-
MODELS AVAILABLE
The air conditioners of the FW-R series are available in two sizes, in the version with refrigerant R410A:
- FW130R
- FW160R
TECHNICAL DATA
Mod.
Cooling capacity
Energy Efficiency Class
EER
Humidity removed
Input power
Input current
Heating capacity with water coil (BVR1)
Water flow rate (BVR1)
Pressure drops (BVR1)
Heating capacity electric coil (BR26)
Fans
Air flow rate
Fans speed
Sound pressure
Water consumption at 30-35°C
Condenser pressure drops
Refrigerant charge R410A
Input nominal power consumption *
Nominal imput current *
Input current
Water connections
Power supply = 230V ~ 50Hz.
Level of sound pressure (A-weighted) measured in an 85 m
semi-reverberant test chamber with reverberation time Tr = 0.5s.
* In accordance with UNI EN-60335
Data declared in accordance with EN-14511
Cooling :
- Room air temperature 27°C B.S. ; 19°C B.U.
- Entering water temperature 30°C
- Leaving water temperature 35°C
- Max speed
22
FWR 1406 - 5388000_02
tion.
They permit the heating in winter when
equipped with the heating coil (water or
electric); they achieve an efficient zone
division of the spaces by the independent
operation of each unit; they ensure an
economy of service by the rapid control
of the ambient conditions by virtue of the
reduced system thermal inertia; and they
operate silently because of the thermo-
acoustic insulation of the compressor.
All the units are completely factory assem-
bled and individually tested
With the FW-R air conditioner the
FW
W (max.)
l/h
W
A
W
l/h
kPa
W
n.
m
/h (max.)
3
m
/h (med.)
3
m
/h (min.)
3
g/m (max.)
g/m (med.)
g/m (min.)
dB (A)
l/h
kPa
g
W
A
A
ø
3
- Room air temperature 20°C
- Entering water temperature 70°C
- Max speed
architectural, aesthetic and acoustic
problems associated with traditional
external air cooled heat exchangers and
fans are resolved.
FW-R must be installed internally, requires
connection to a water network and has
limited water consumption.
The unit contains the entire refrigerant charge
of R410A
130R
2900
A
4.08
1.78
710
3.55
4350
600
12,6
1200
2
470
390
270
800
660
500
44
586
22
750
1120
4.97
18
1/2"F
Heating (BVR1) :
160R
4000
A
4.65
1.78
860
4.02
5200
600
12,6
1200
2
690
525
375
1140
885
665
47,5
804
40
830
1500
6.65
32
1/2"F