HTRONIC PLS1000 Mode D'emploi page 80

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

„HUMIdIFy" FUnCTIOn In TF-SwITCHIng MOdE
The „Humidify" function is set when the set switch-on humidity value is less than
the switch-off humidity value. The control is carried out by the relay F1 or F2.
Behavior of relay F1 or F2
Abbreviations:
F1
measured relative humidity at the indoor sensor
F1 EIn
setpoint for the switch-on humidity
F1 AUS
setpoint for the switch-off humidity
Relay F1 turns on when F1 ≤ F1 On
Relay T1 is switched off when F1 ≥ F1 OFF
nOTE: All relays are switched off if the indoor sensor or outdoor sensor is
faulty or not connected.
80 |
80 |
78 |
Modes/programs/functions
HUMIdIFy
HUMIdITy
F1 OFF
F1_AUS
F1 ON
F1_EIN
Switch-on point
F1(2)
F1(2)
hysteresis
TIME
Switch-off point
Hysterese
Hysterese