MAKE THE ELECTRICAL CONNECTIONS
WARNING: To avoid possible electrical shock, be sure you have turned o the power
at the main circuit panel before wiring. Follow the steps below to connect the fan to
your household wiring. Use the wire connectors supplied with your fan. Secure the
connector with electrical tape. Make sure there are no loose wire stands or connections.
WARNING: If your house wires are di erent colors other than referenced in this manual,
stop immediately. A professional electrician is recommended to determine proper wiring.
Step 1. Connect the BLACK wire from the fan to BLACK wire marked "TO MOTOR L"
from the wall control. (Fig.12)
Step 2. Connect the BLUE wire from the fan to BLUE wire marked "FOR LIGHT" from
the wall control.(Fig.12)
Step 3. Connect the WHITE wire from the fan to the household neutral WHITE wire.(Fig. 12)
Step 4. Connect the BLACK with WHITE stripes wire marked "AC IN L" from the wall control
to the household BLACK/WHITE supply wire.(Fig. 12)
Step 5. Connect GROUND(GREEN) wires from mounting bracket and downrod ball and wall
control, to GROUND(GREEN) or BARE(COPPER) wire from house.(Fig.12)
Step 6. Secure the wire connection with plastic
wires, spread them apart so that the green and white wires are on one side of the outlet box.
black and white stripes wire and blue wire are on the other side. (Fig. 12)
NOTE: Carefully tuck the wire connections up into the outlet box.
10
connectors
provided. After connecting the
Green or bare copper (ground)
AC IN N( White)
AC IN L(Black/white)
Wall Control
Ground/Earth
B/W ("AC" IN L")
Blue(for light)
Black ("TO MOTOR L")
Black (motor)
Ground wire
Blue( light)
White (Neutral)
Fig. 12