Ribimex Ribiland PRSWIM370/1 Manuel D'instructions Et D'utilisation page 18

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Never try to clear the turbine while the pump is still connected to the mains power.
3. The pump is equipped with a motor protected by a thermal protection with auto-restart.
In case of overheating, the motor stops automatically. As soon as the temperature returns to normal,
the engine restarts.
Do not approach hands around the turbine during this phase.
If an intervention is necessary, remove the plug from mains power socket.
4. The pump must not be used to suck corrosive liquids or solids, combustible or explosive. Do not
use to pump food liquids (e.g. water, fruit juices, alcohol beverages...)
The max temperature of water should not exceed 35 ° C.
Any other use different from that stated in these instructions may cause damage to the pump and pose
a serious danger to the user
VI- Maintenance
Before any intervention on product, ensure that product is disconnected form its
power source.
6.1- Cleaning
- Carry out regular pump rinsing with clear water.
- Avoid pumping liquid containing abrasive materials, sand ...
- Before re-starting; ensure the proper condition of each part.
- Filter cleaning: rinse regularly or when the first sign of malfunction appears
- If not located in a frost- free location (e.g. open-air pools), ensure that circulating pumps are
drained during winter together with the filter plant.
This is done by undoing the drain plugs (7) at the pump with suitable tool.
The PVC screws are prone to damage. Drain plugs to be fastened hand-tight only.
- The lint strainer (9) must be checked and cleaned from time to time.
- The O-ring gasket (5) and its seat must be kept clean.
- The filter gasket (8) must be repositioned such that the groove at the top ring fits the locating knob
in the seating of the strainer housing.
- Before re-starting; ensure that o-rings are in good condition and check proper assembly of
connection to avoid any leakage.
- In the case of a pump failure, first switch-off the motor; the stator housing can then be separated
from the pump housing by undoing and removing the eight holding -down screws (10). When
re-assembling, ensure correct seating of the two O-ring washers (8).
Screws to be tightened cross- wise. Removal and re- assembly of the stator housing must only
be done by qualified personnel.
- For repair or maintenance that requires disassembly of electrical parts, it is imperative to contact
qualified personnel or a service centre (see your local reseller).
Do not use any other cleanser than water
Do not use aggressive cleansing agents (e.g. solvents, detergents) or an abrasive sponge or any
sharp object.
6.2-Troubleshooting
Never attempt to disassemble the pump. If necessary, have your pump maintained and repaired by an
authorized service centre.
6.3-Storage
it is recommended to store the product in a dry clean place, out of children's reach, either in height or
locked up.
CAUTION The exterior of the filter pump must be protected from moisture!

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Ribiland prswim550/1Ribiland prswim750/1519466519476519486

Table des Matières