2. Safety Warnings

2.1. General Instructions
Signs used to mark instructions in this manual
Safety instructions in these operating instructions,
which, if not observed, could cause a danger for persons
are marked with the general symbol in accordance with
DIN 4844-W 9.
Warnings against electrical voltage are marked with
the safety symbol in accordance with DIN 4844-W 8.
2.2. General Safety Precautions
General regulations and guidelines not mentioned in the
safety warnings retain their validity.
These operating instructions contain basic
instructions, which have to be adhered to during
installation, operation and maintenance. These operating
instructions must be read from mechanic and the operator
before installation and operation of the pump and have to
be kept available at the operating place of the
machine/unit at all times. Persons who are not familiar
with the operating instructions shall not use this product.
Children and adolescents under age 16 shall not use
the unit and must keep away from the machine/unit
while it is operational.
The unit must be installed from a technical
experienced plumber.
Never work alone.
Please make sure that used aids e.g.hoisting crane
are in regular and reliable contiditions.
The working area has to be closed off expediently
and must adhere to local workplace regulations.
Always use personal safety equipment such as safety
boots, rubber gloves, safety glasses and helmet.
Make sure that the emergency exit from the
workplace is not barricaded.
To prevent suffocation and poisoning caused by
venomous gases, make sure that enough oxygen exists at
the workplace.
If you have to work with welding tools or electric tools,
make sure that there is no explosion hazard.
Immediately after repair or maintenance work, all
safety and protection equipment must be reinstalled and
placed in function again.
The operator of the pump is responsible for third
parties within the work area.
All other rules and regulations and local codes
covering health and safety must be observed. In
accordance with product liability law, we point out that we
shall not be liable for damages caused by the pump due
to non-observance of the instructions and guidelines set
forth in the operating instructions. The same product
liability are valid for accessories.

3. Applications and Technical Description

3.1. Applications
The pump station SK 6 or SK 9 is used as an underfloor
pump station for pumping domestic drainage water and
waste water.
The pump station will be installed in building which are
below the sewer level or have not enough natural fall to
the canalisation.
The mounted auto-coupling system and discharge pipe
reduve installation work to a minimum. Bevor the pumping
of chemically aggressive liquids, the resistance of the
materials must be checked.
3.2. Product Description
Smell-tight and watertight pump station with one or two
pumps. The pump station consists of a collecting tank with
all necessary ports for the connection of inlet pipe,
discharge pipe and air vent.
The pump station SK 6 or SK 9 with GRP pumps are
equipped with a cutter system at the pump inlet which
cuts all soft solids to small particles, so that the liquid may
be pumped through small diameter discharge pipes of
40 mm ø.
3.3. Technical Data
Inlet, combined
Connection for airvent, cable duct
Discharge
Frame for shaft cover resp. rings for
height adjustment
Applicable pump models
Applicable control panels
3.4. Operation Conditions
Please pay attention to the installation and
operation instruction manual of the installed
submersible pumps and control panels.
3.5. Explosive Environments
For operation of the pumps in explosive environments
only models with explosion-proof motors (Ex model) must
be used.
For each individual installation the explosion
classification (Ex-class) of the pump must be approved by
the localauthorities.
4. Warranty
Our warranty only covers pumps which are installed and
operated in accordance with these installation and
operation instructions and accepted codes of good
practice and being used for the applications mentioned in
these instructions.

5. Transport and Storage

The pump station may be transported and stored in
vertical position. Make sure that it cannot roll or fall over.
For longer periods of storage, the pump should be
protected against moisture, solar radiation, frost or heat.
9
DN 100 / DN 150 /
DN 200
DN 100
BSP 1 ½" M
800 mm
TP 30 M
TP 30 V
TP 50 M
TP 50 V
TCV
TCM
GRP
PS 15
PS 25