Installation; Duct Installation - Kozy Heat Fireplaces HTK-INT Manuel D'installation

Kit de transfert de chaleur intérieur. pour utilisation avec modèles aby, alp-36s, bhm44, bhm-52, clw-40, clw-50, clw-72 et sfd-36
Masquer les pouces Voir aussi pour HTK-INT:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

2.0 INSTALLATION

2.1 Duct Installation

NOTE: The fan assembly can be installed on the wall, minimum 4"
(102mm) from the floor or the ceiling. It can also be installed on the
ceiling.
1.
The outer shell of your fireplace will have square cover plate(s)
for use with heat transfer kits. Reference the fireplace manual for
the location of your heat transfer kit cover plates. See Figure 2.1.
2.
Remove screws securing cover plate(s) on the rear of the outer
shell of the fireplace.
3.
Remove the damper from the heat transfer kit air chute by
pushing the metal tab through the hole and pulling the damper
out of the air chute. See Figure 2.2. Your air chute may look
different than the one shown. Attach the HTK air chute to the
fireplace as per instructions included with HTK air chute.
4.
Use the nailing flanges attached to the air discharge box to
secure it to the framed opening at the desired location for air
discharge.
5.
Attach and secure the 3.25" x 10" x 6" boot to the top of the air
discharge box using sheet metal screws.
6.
Cut the insulated flexible duct to necessary length.
7.
Place the band clamp over the HTK air chute collar. Screw the
inner liner of the flexible duct to the collar with (3) sheet metal
screws. See Figure 2.3.
8.
Use the band clamp to secure the outer flexible pipe insulation
to the inner pipe and collar. See Figure 2.4.
9.
Repeat Steps 7 and 8 to attach and secure the flexible pipe to the
duct boot on the air discharge box.
NOTE: If you choose to attach the air discharge box to a wall stack
with S cleats, your installation steps may vary. A right angle boot may
be needed instead of the provided straight boot. Attach the insulated
flexible pipe from the HTK air chute to the boot on the wall stack that
would connect to the air discharge box.
Figure 2.1, HTK Square Cover Plate Removal (1) Shown
Heat Transfer Kit #HTK-INT R.7
Figure 2.2, Damper Removal
Figure 2.3, Band Clamp over HTK Air Chute Collar
Figure 2.4, Band Clamp Securing Outer Insulation to Inner Pipe and Collar
Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces
PUSH TAB THROUGH
HOLE TO REMOVE DAMPER
DISCARD DAMPER
AIR CHUTE WITH DAMPER REMOVED
9