1.4.3 Shelf Requirements
WARNING: LEAVE THIS SPACE CLEAR OF CONTENTS!
Figure 1.9 shows the shelf requirements for models ABY, BHM-52,
CLW-40, CLW-50, CLW-72, and SFD-36 when the air discharge opening
is located in a shelf or a built-in cabinet.
Figure 1.10 shows the shelf requirements for model ALP-36S when
the air discharge opening is located in a shelf or a built-in cabinet.
2"
MIN
(51mm)
2"
MIN
12"
MIN
(51mm)
(305mm)
18"
MIN
(457mm)
Figure 1.9, Shelf Requirements for ABY,BHM-52, CLW-40, CLW-50, CLW-72, and SFD-36
8
For models ABY, BHM-52,
CLW-40, CLW-50, CLW-72, and SFD-36
18"
(457mm)
MAX
Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces
10"
MIN
(254mm)
½
6
"
24"
MIN
MIN
(165mm)
(610mm)
18"
MIN
(457mm)
Figure 1.10, Shelf Requirements for ALP-36S
For model ALP-36
18"
(457mm)
MAX
Heat Transfer Kit #HTK-INT R.7