1.4 Dimensions and Clearances

Model #SFD-36 corner installations have different minimum
dimensions to allow space for the SFD-HTK air chute. See appliance
installation and operation manual for more information.
Figure 1.3 shows the dimension of the air discharge box with the
boot attached.
Figure 1.4 shows the depth of the boot.
Figure 1.5 shows the 4" (102mm) clearance between the air
discharge box and the framing of the floor or the ceiling.
Figure 1.6 shows an optional installation method of using 3.25"
x 10" wall stack with S cleats attached to the air discharge box.
The figure also shows an angled 3.25" x 10" x 6" boot that may be
needed for certain installations. The wall stack application has to
start after achieving the minimum 3' (914mm) run of insulated
flex pipe to the boot. The wall stack is 0" (0mm) clearance to
combustibles. The wall stack and angled boot are not provided.
Figure 1.7 on the following page shows finishing clearances.
½
5
"
(140mm)
½
15
"
(394mm)
Figure 1.3, HTK-INT Dimensions
Figure 1.4, HTK-INT Dimensions - Side View
Heat Transfer Kit #HTK-INT R.7
6" (152mm) dia.
11
"
(290mm)
¼
3
(83mm)
4"
(102mm)
6
"
(169mm)
Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces
Figure 1.5, HTK-INT Ceiling and Floor Clearances
THIS OPTIONAL APPLICATION HAS TO START
AFTER ACHIEVING THE MINIMUM 3' (914mm)
RUN OF INSULATED FLEX PIPE TO THE BOOT
"
Figure 1.6, HTK-INT Wall Stack (optional installation)
½
14
"
(368mm)
24"
(610mm)
4"
(102mm)
3.25" x 10" x 6"
ANGLED BOOT
(not provided)
3.25" x 10"
WALL STACK
(not provided)
#HTK-INT