3.0 ELECTRICAL INFORMATION
3.1 Electrical Requirements
•
#HTK-INT operates on 120VAC, 60Hz electrical service
•
Disconnect electrical service before servicing.
•
The on/off switch and/or fan speed control must be able to
handle a rating of 0.5 amps
3.2 Electrical Wiring
•
ITEMS SUPPLIED: Wiring leads from the fan, wiring nuts, and a
green ground screw will be attached to the air discharge box.
POWER SOURCE
Figure 3.1, HTK-INT Wiring Diagram
12
ON/OFF
SWITCH
Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces
•
NOTE: Wiring and switches/speed control are not supplied.
•
Figure 3.1 illustrates a typical wiring installation. Hard wire the
fan to the electrical system.
•
It is easier to access the ground screw if you remove the (2)
flange nuts securing fan to the assembly and slide the fan
forward.
•
Secure grounding wire to the grounding screw installed in fan
assembly housing.
•
Connect the fan to the speed controller and test the fan
operation.
FAN SPEED
CONTROL
GROUND WIRE
GROUND SCREW
WIRE NUTS
Heat Transfer Kit #HTK-INT R.7