3.0 ELECTRICAL INFORMATION

3.1 Electrical Requirements

#HTK-INT operates on 120VAC, 60Hz electrical service
Disconnect electrical service before servicing.
The on/off switch and/or fan speed control must be able to
handle a rating of 0.5 amps

3.2 Electrical Wiring

ITEMS SUPPLIED: Wiring leads from the fan, wiring nuts, and a
green ground screw will be attached to the air discharge box.
POWER SOURCE
Figure 3.1, HTK-INT Wiring Diagram
12
ON/OFF
SWITCH
Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces
NOTE: Wiring and switches/speed control are not supplied.
Figure 3.1 illustrates a typical wiring installation. Hard wire the
fan to the electrical system.
It is easier to access the ground screw if you remove the (2)
flange nuts securing fan to the assembly and slide the fan
forward.
Secure grounding wire to the grounding screw installed in fan
assembly housing.
Connect the fan to the speed controller and test the fan

operation.

FAN SPEED
CONTROL
GROUND WIRE
GROUND SCREW
WIRE NUTS
Heat Transfer Kit #HTK-INT R.7