Upload
During the upload, data are transferred from the basic device to the memory card.
)
Note!
The data transmission basic device®card module (upload) can also be
ƒ
carried out while the IEC 61131 program is running and controller inhibit
(for 9300 servo PLC/ECSxA) is deactivated.
When the AIF access protection (C0096/1 ¹ 0) is activated, data
ƒ
transmission is impossible.
If the connection is lost during data transmission (e.g. because the card
ƒ
module is unplugged or because of a voltage failure), all data records on
the memory card may be lost!
A cancelled data transmission cannot be continued, but has to be restarted
ƒ
again.
If the drive set is saved on the card by means of an upload, the option
ƒ
"Carry out reset (source) at download" is activated automatically. The card
module then carries out a reset (source) before the download to a basic
device.
Carrying out an upload
1. Insert the memory card in the card module (^ 34).
2. Plug the card module onto the AIF interface of the basic device. (^ 32).
The 7−segment display
3. Press key T3 repeatedly until the 7−segment display indicates the program memory
location on which the data of the basic device are to be saved.
If the yellow LED is lit, data are already stored on the program memory location selected.
These data will be overwritten in the case of an upload.
4. Press key T2 to start the upload.
During the upload, a rotating/stationary bar is shown on the 7−segment display. After
the upload has been carried out successfully, the program memory location selected is
shown again.
EDKMZ2221IB DE/EN/FR 7.0
0
indicates that the card module is ready for operation.
l
Operation
4
Upload
35