WARNING! If installing optional Shroud/Slip Ring or Towel Dispensers, complete those installations
before proceeding to Step 3 (see next page).
3
Connect Drain
Off-Line Vent (Type A or O): Connect 1-1/2" P-Trap and
drain piping (supplied by installer) to the drain spud.
Centrally Rising Vent (Type B or H) or models with
optional paper towel dispensers: Connect the vented
P-Trap (provided) and drain piping as shown:
4
Turn on Water, Test and Adjust Unit
Check to make sure stop valves are open
before turning on water.
A
Turn on water supply and check for leaks. Activate
each push/foot button to purge air from the lines.
Loosen the cap screw about
C
¼" (4–6 turns) and lift up
the cover (do not remove).
Using the cover, turn
the cartridge gently until
desired water temperature
D
is reached. Do not turn past
stops as this may damage
the unit. Push the cover
down and tighten the screw.
6
H
12/04/2012
Strainer
Drain Spud
Tailpiece
P-Trap
B
Adjust air-valve meter timing, if desired
(hand-operated units only).
Air Metering Timer
(Hand-operated push button only)
This valve is NOT factory preset.
Upon installation, the temperature
of this valve must be checked and
adjusted to ensure delivery of a safe
water temperature. Water in excess
C
of 110°F (43°C) may cause scalding.
Bradley • 215-1066 Rev. H; ECN 12-00-004
Installation
1-1/2" NPT Vent Pipe
(supplied by installer)
1-1/2" NPT Tee
1-1/2" NPT Close
Nipple
1-1/2" Drain
(supplied by installer)
-
+