Bradley SN2005/AST4 Manuel D'installation page 4

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

SN2005/AST4, SN2005/AST4-F
Rough-In Dimensions for Supplies and Drain
Notes
Maximum flow rate required to washfountain is 1.5 GPM. Size supply lines
accordingly.
Supplies from Below: Stub up 2-1/2" (64).
Supplies from Above: Supplies must be located on centers of dimensions shown to
pass through washfountain shroud and sprayhead.
Drain through floor: Stub up 3" (76).
Supplies from Below or Through Wall
Top View
3-1/4" (83)
UPC and IPC restrict the vertical distance from the fixture outlet to the trap weir to not more than 24"
(610). Check state and local codes for variances.
4
Type A
Off-line vent
(P-Trap supplied by
Installer.)
Type H
Centrally rising vent -
passes through center of unit
(P-Trap furnished).
4-1/2"
4-1/2"
(114)
(114)
H
C
Type H
5"
(127)
Type A
12/04/2012
1/2" Supply: Nominal Copper Tube
1-1/2" NPT Drain
Supplies from Above
Type B
Centrally rising vent -
(P-Trap furnished) Use for units
with paper down dispensers and/
or shrouds.
Type O
Off-line vent
(P-Trap supplied
by Installer.)
Top View
H
27/32" (21)
27/32" (21)
5"
C
(127)
1-3/16"
(30)
Bradley • 215-1066 Rev. H; ECN 12-00-004
Installation
(mm)
Type B
Type O