* Re-setting the Maximum Temperature
These models have a default maximum temperature of 120º F (49º C)
and an option to increase the maximum temperature to 140 ºF (60 ºC).
Temperature settings from 125-140 ºF (52-60 ºC) are available by
setting switch 6 to ON in the SW1 bank of 8 switches.
** MCC-91 Temperature Controller
These settings require the MCC-91 controller. When the MCC-91
controller is connected, these higher temperatures are available on all
controller models in the system. Use of an MCC-91 controller in a
residential dwelling will reduce the warranty coverage to that of a
commercial warranty application.
The MCC-91 controller is intended for commercial and hydronic
applications only. If an MCC-91 controller is used in a residential
dwelling for a hydronics application, a mixing valve must also be
installed to limit the potable hot water temperature to a safe
temperature. Water temperatures over 125º F (52º C) can cause severe
burns or scalding. Refer to the Danger Alert on water temperatures.
Rinnai shall not, in any event, be liable for damages resulting from such
misuse or misapplication.
Suggested temperatures are
Kitchen
120 ºF (49º C)
Shower
98 - 110 ºF (37 - 43 ºC)
Bath Fill
102 - 110 ºF (39 - 43 ºC)
These temperatures are suggestions only.

Temperature Options Without a Temperature Controller

The default temperature setting for this appliance installed without a temperature controller is 120º F (49º C). If
desired, the temperature setting can be changed to 140º F (60º C) by adjustment of a switch.
In the SW1 bank of 8 switches, set switch 5 to ON to obtain 140º F (60º C) water temperature setting. Set switch
5 to OFF (default) to obtain 120º F (49º C) water temperature setting.
If a temperature controller is installed, then switch 5 has no effect on temperature settings.
Setting the Sound Volume (Voice Prompt)
MC-100V
Medium Volume
(default)
8
Press the "Function" button to
adjust the voice prompt
volume. The default sound
volume is set to Medium.
Each subsequent press of the
▲ or ▼ button cycles through
the volume levels in the order
below.
High Volume
Manual - Rinnai Condensing Water Heaters
A temperature lower than 98º F (37º C) can be
obtained at the tap by mixing with cold water.
To change the temperature scale from Celsius to
Fahrenheit or vice versa, press and hold the "On/Off"
button for 5 seconds while the water heater is OFF.
BC-100V
Off Volume
Off Sound
(beep)
(no beep)
Maximum Temperature
120º F (49º C)
140 ºF (60 ºC)
Switch No.
Switch No.
ON
O
1
F
2
F
3
4
5
6
7
8
WARNING
DO NOT adjust the other switches
unless specifically instructed to do
so.
Press the "Sound Vol." button to
adjust the voice prompt volume.
The default sound volume is set
to Medium. Each subsequent
press of the button cycles
through the volume levels in the
order below.
Low Volume
ON
O
1
F
2
F
3
4
5
6
7
8