Dimensions And Specifications; Clearances; Gas Pressures; Gas Inlet Size - Garland G Serie Manuel D'installation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

DIMENSIONS AND SPECIFICATIONS

Clearances

Clearances Applicable For All Models
Surface
Combustible Wall Minimum
Non-Combustible Wall Minimum

Gas Pressures

Minimum Supply
Gas
Pressure
Natural
7" WC (17.5 mbar)
Propane
11" WC (28 mbar)

Gas Inlet Size

Model Width
24" (610mm) &
36" (914mm)
48" (1219mm) &
60" (1524mm)

Individual Burner Input Rates

Open Top
Hot Top Burner (In lieu of 2 open top burners)
Griddle Burner (In lieu of 2 open top burners)
Raised Griddle Broiler (Consists of 3 burners)
Oven Burner For Full Size Standard or Convection Oven
Space Saver Oven
Rates are for installations up to 2000' (610m) above sea level
Page 4
Sides
14" (356mm)
0"
Manifold Operating
Pressure
4.5" WC (11.25 mbar)
10" WC (25 mbar)
Connection
3/4" NPT
Rear Gas Connection
1" NPT
Rear Gas Connection
Burner
Rear
6" (152mm)
0"
Input BTU/HR
Natural
Propane
Gas
Gas
33,000
26,000
18,000
18,000
18,000
18,000
33,000
33,000
38,000
32,000
32,000
28,000
Part # 4523104 Rev 3 (03/04/10)