7-4. Inspecting Filter And Spark Guard

OM-260 545 Page 26
2
!
Turn off power and discon-
nect input power cord.
!
Do not operate unit without fil-
ter or with dirty filter.
!
Clean or replace the filter
when dirty.
!
Do not breathe the particles
collected by the fume extrac-
tor. Wear approved safety
equipment (respirator, gloves,
long sleeve shirt) when ser-
vicing filter and spark guard.
Dispose of used element and
collected particles according
to local, state, and federal re-
quirements.
!
Read and understand the
Safety Data Sheets (SDSs)
and the manufacturer's in-
3
structions for metals, con-
sumables, coatings, cleaners,
and degreasers.
1
Door
2
Filter
3
Spark Guard
Release latches and open door. Re-
leased latches on filter. Use filter
1
handle to remove filter.
Clean or replace filter if dirty or dam-
aged.
Wipe off door. Remove particles from
inside of housing.
Remove spark guard (from behind
baffle).
Clean and inspect spark guard
screen. Replace spark guard if
screen wires are broken or missing.
Check gaskets on access door,
particle tray, and front and back of fil-
ter. Replace gasket(s) if damaged.
Install spark guard.
Install filter and secure with latches.
.
Verify filter is securely latched.
The safety interlock system pre-
vents unit from starting if filter is
not properly latched.
Close door and secure with latches.
Tools Needed: