Section 5 − Installation; Selecting A Location - Miller FILTAIR Manuel Du Propriétaire

Masquer les pouces Voir aussi pour FILTAIR:
Table des Matières

Publicité

5-1. Selecting A Location

Extend lifting forks
beyond center of skid.
18 in
(460 mm)
SECTION 5 − INSTALLATION
2
!
Do not move or operate unit
where it could tip.
!
Do not use this equipment to
support
tools, or other material.
!
Special installation may be re-
quired where gasoline or vola-
tile liquids are present − see
NEC Article 511 or CEC Sec-
tion 20.
.
Unit shown with extraction arm
already installed.
1
Lifting Forks
2
Caster w/Brake
3
Three-Phase, 460 Volt AC or
1
575 Volt AC depending on
machine model. Power Supply
− Line Disconnect Device
4
Compressed Air Supply
(80−100 psi/3.8−4.8 kPa)
Use wheels or lifting forks to move
unit.
If using lifting forks, extend forks be-
yond opposite side of small contain-
ers and beyond midpoint of large/
long containers.
3
Position unit near the welding opera-
tion and close to compressed air sup-
ply and 460 volt AC input power sup-
4
ply. Keep unit away from obstructions
that may restrict movement of the
fume collector or extension arm.
.
A three-phase, 460 volt AC or
575 volt AC individual branch cir-
cuit protected by time delay (type
D) fuses or circuit breaker is re-
quired.
personnel,
large
800 402-A / 260 887-B / 161-016
OM-260 545 Page 15