5-8. Connecting Input Power

!
Installation must meet all National
and Local Codes − have only quali-
fied persons make this installation.
!
Disconnect and lockout/tagout in-
put power before connecting input
conductors from unit. Follow estab-
lished procedures regarding the in-
stallation and removal of lockout/
tagout devices.
!
Always connect green or green/yel-
low conductor to supply grounding
terminal first, and never to a line ter-
minal.
!
Do not use the fume extraction
equipment unless you are sure it is
correctly assembled and working
properly.
See rating label on unit and check input volt-
age available at site.
OM-260 545 Page 20
1
Input Power Conductors (Customer
Supplied Cord)
Select size and length of conductors using
Section 5-7. Conductors must comply with
national, state, and local electrical codes. If
applicable, use lugs of proper amperage
capacity and correct hole size.
Disconnect Device Input Power Connec-
tions
2
Disconnect Device (switch shown in
OFF position)
3
Disconnect Device (Supply)
Grounding Terminal
4
Disconnect Device Line Terminals
5
Input Conductors L1 (X), L2 (Y), And
L3 (Z)
Connect green or green/yellow grounding
conductor to disconnect device grounding
terminal first.
3
3
5
1
8
7
Input 8 2012−11 / 260 889-B / 261 487-A
Connect input conductors L1 (X), L2 (Y)
And L3 (Z) to disconnect device line termi-
nals.
6
Over-Current Connector
Select type and size of over-current protec-
tion using Section 5-7 (fused disconnect
switch shown).
7
Input Power Connector
See Section 5-6.
8
Input Power Receptacle
(Machine-Mounted)
Connect input power connector to input
power receptacle.
Close and secure door on line disconnect
device. Follow established lockout/tagout
procedures to put unit in service.
2
6
4