SOMFY M8 Notice D'installation page 7

Masquer les pouces Voir aussi pour M8:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 9
EN
A
MOUNTING
n For exact determination of wind and brightness direction the
Weather Station must be mounted in north alignment (N).
The place where the sensor is installed might have an impact on
the measured values.
[1] Façade mounted versions
[2] Roof mounted version
1
Mounting with Somfy accessories (
Ø 50 mm.
2
Mounting on already existing mast Ø 25 mm.
3
Mounting on already existing mast Ø 50 mm with
Bracket for Weather Station (
[3] n Weather Station must always be installed upright, not
horizontal or in an angle.
B
WIRING
n Use rigid cable.
n If a hole has been drilled in the mast during installation
of the unit to fit the cable through, the cable may be dam-
aged by sharp edges.
m The cable for connection of the Weather Station must be
suitable for permanent outdoor use and compliant to the
relevant standards.
7 minutes after switching on the device, the flashing LED
indicates normal operation.
C
TOPOLOGY
Accessories
Mast Adaptor
for Weather Station
Ref. 1860321
Dimensions
H: 90 mm/Ø 25 - 50 mm
Sensors
M8
Wind speed
Wind direction
Brightness
Temperature
Precipitation
CABLE
Connection to ...
Cable
Power Supply
Min.: 2 x 0.28 mm
RS485 Bus
Min.: 2 x 0.28 mm
We care about our environment. Do not dispose of the appliance with usual household waste. Give it to an approved collection point for recycling.
7/20
- animeo Weather Station M8/M13 . Ref. 5146655C
1-3
) on a mast
4
).
Metallic Mast
1
Ref. 1860335
H: 1 m/Ø 50 mm
M13
Measuring Range
0...35 m/s
1...360°
)
0...100 klux
(x4
(x8)
- 30...+ 50° C
1/0 (precipitation yes/no) Thermal output, sensor dry, bedewing protection: 0.1 W
2
/22 AWG - Max.: 2 x 0.5 mm
/22 AWG - Max.: 2 x 0.5 mm
2
As the device works without moving parts, i.e. wear-free, only a
minimum of service work is required.
Depending on the location, the device may become dirty. The device
should be cleaned with water and a soft cloth.
 
m During storage, assembly, disassembly, transport or maintenance
of the Weather Station, ensure that no water enters the unit or plug.
CHARACTERISTICS
Weather Station M8/M13
Supply voltage
Power Supply
Max. current
Operating temperature
Material of housing
Housing dimensions (h, Ø)
Weight
Protection class
Degree of protection
Conformity
Wall Mount Bracket
2
Ref. 1860336
200 x 90 x 30 (w
d
x
Resolution
Accuracy
0.1 m/s
± 5 % (± 1 m/s) rms over 360°
± 5° with laminar flow and windspeed > 2 m/s
0.1 klux
± 200 Lux with < 2 kLux; ± 10 % with ≧ 2 kLux
0.1° C
± 1° C with laminar flow and windspeed > 2 m/s
Thermal output, sensor wet, drying phase: 1.1 W
Twisted pair
2
/20 AWG
Required
/20 AWG
2
24 V DC + 10 %/- 30 %
Mandatory use of certified power
supply with limited power (certified
according to the relevant version of
60950-1 or 62368-1, EN/IEC or UL as
needed in the country of use).
Limited power classified as LPS, PS2
or UL class II (according to standard)
230 mA@24 V
- 30° C...+ 70° C
Polycarbonate
105 mm, 103 mm
162 g
IP44 in working position
www.somfy.com/ce
Bracket
3
4
for Weather Station
Ref. 1860320
h)
180 x 80 x 80 mm
x
Max. length
500 m

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

M1318603061860307Weather station m 8Weather station m 13

Table des Matières