3. Rinse the transducer with clean water.
How to clean the basin unit:
1. Clean the water basin with soft cloth and the cleaning abluent if there is scale in it.
2. If the scale is covered on the security switch, drop the cleaning abluent on the scale
and clean it out with the brush.
3. Rinse the water basin with clean water
TROUBLESHOOTING
Problem

Possible causes

Power lamp off,
No power supply
does not work
Power lamp on,
No water in water tank
no mist outlet
Security switch is too loose
with fan
New unit
Abnormal mist
smell
Dirty water or water sitting
too long
Power lamp
Too much water in the water
on, unit doesn't
basin
work
Too much scale in the water
basin
Mist fog is too
low
Water is too dirty or water
left in the tank too long
Solution
Connect power supply, switch
on
Fill water tank with water
Tighten the switch
Remove water tank, open
cover, let it stand 12 hours in
a cool place
Clean water tank, fill with
fresh water
Remove some water from the
water basin, tightly close the
cover of water tank
Clean transducer
Clean water tank, replace
with fresh, clear water
EN