Input Data For Thermocouples (Tc) - Knick ThermoTrans P 32100 P0 Série Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Specifi cations

Input Data for Thermocouples (TC)

Sensor
(Standard)
type
B
(DIN 60584-1)
E
(DIN 60584-1)
J
(DIN 60584-1)
K
(DIN 60584-1)
L
(DIN 43710)
N
(DIN 60584-1)
R
(DIN 60584-1)
S
(DIN 60584-1)
T
(DIN 60584-1)
U
(DIN 43710)
W3Re/W25Re (ASTM E988-96)
W5Re/W26Re (ASTM E988-96)
Input resistance
Max. line resistance
Line monitoring
Accuracy
Temperature coeffi cient at
input
Cold junction compensation
Error of external
cold junction compensation
Error of internal
cold junction compensation
54
Range [°C]
250 ... 1820
- 200 ... 1000
- 210 ... 1200
- 200 ... 1372
- 200 ... 900
- 200 ... 1300
- 50 ... 1767
- 50 ... 1767
- 200 ... 400
- 200 ... 600
0 ... 2315
0 ... 2315
> 10 MΩ
1 kΩ
Open circuits
± (10 μV + 0.05 % meas.val.) for
spans > 2 mV
50 ppm/K of adjusted end value
(average TC in permitted operating
temp range, reference temp 23 °C)
Internal
Via IrDA: external or fi xed value
Via Pt100 for T comp = 0 ... 80 °C:
± (80 mΩ + 0.1% meas.val.)
± 1.5 °C
Selectable via
IrDA only
x
x
x
x
x
x
x
x
x
x