E L E C T R I C A L C O N N E C T I O N
The heater is designed for permanent connection to a wall jack
or socket.
The device is connected to the AC mains system by putting the
power cord into a connection socket.
NOTE
The connecting cable can be extended using a cable of the
H05VV-F3G1,50 type. A direct connection to a permanently laid
cable may only be implemented up to a diameter of 1.5 mm²
(e.g. NYM-J3G1,5 mm²). The length of the connecting cable
must be between 1.0 and 1.9 m.
An all-pole disconnecting device with a minimum contact open-
ing width of 3 mm has to be mounted into the fixed electrical
installation in compliance with the installation regulations.

HEATING MODE

The heater is operated by means of direct connection via
switch, via an external room thermostat, via timer or controller
directly on the device or via a radio receiver in connection with a
radio-controlled room thermostat. These items can be ordered
as accessories. Please observe the operating instructions
of the respective product.
U S E R M A N U A L
HEATING MODE
The infrared heating has a very large radiation component
and a very small convective component of the heating power.
For reasons of safety, the surface temperature is max. 80 °C,
therefore LAVA
BATH suits ideally as zone heating and thanks
®
to the included towel holder as towel heater as well.
The infrared heating by ETHERMA mainly heats solid objects
and, only to a lesser extent, directly heats the room air. There-
fore, these devices are ideal for additional temperature control.
Depending on the size of the device, the infrared heating re-
quires a certain time until the operating temperature is
reached. Only then the radiation can take its full effect.
The glass panel produced for the product consists of 6 mm
single-pane safety glass (ESG). This is much more resistant
in contrast to conventional glasses and is designed for signif-
icantly higher impact forces. Nevertheless, you should avoid
12
Dimensional drawing: Connection circuit diagram
ATTENTION:
If the main cable to the device is dam-
aged, it must be replaced immediately by a spe-
cialist.
excessive stress. In case of damage, ESG shatters into many
small parts with blunt edges, so that the risk of injury is min-
imized. When choosing the place of installation, please note
that a negligible amount of tempered glass still causes a so-
called "spontaneous breakage", which means that the glass
shatters even without external influence. Therefore, choose
the installation location of the device in such a way that even in
these cases no danger to persons or objects is to be expected.

MAINTENANCE AND CARE

The infrared heating is designed so that it gives off its heat via
the surface in the form of radiation. The device does not con-
tain any parts requiring special maintenance. In order to ser-
vice your infrared heater, we recommend using a damp cloth.
Please do not use any scouring agents, since they may leave
scratch marks on the surface.
ATTENTION:
When you want to clean the infrared
heating, the heating device must be cold!