N O T E S
› LAVA
infrared heating devices comply with the relevant
®
safety requirements.
› Installation and initial start-up, as well as repairs and servicing,
may be carried out by a licensed specialist or qualified individ-
ual only. All safety regulations must be observed. This person
must verify first whether the electrical in-house system com-
plies with the relevant standards. The responsibility of the
manufacturer is limited to supply of the device.
› Comply with country-specific safety regulations.
› Comply with local safety precautions.
› The devices are suitable for the installation on walls and on
ceilings.
› Protective areas must be observed in accordance with DIN
VDE 0100, part 701, when installing the device in bathrooms.
› Minimum distances must be adhered to.
C L E A R A N C E S
INSTALLATION AND MINIMUM DISTANCES:
LAVA
infrared heating devices have to be mounted so that
®
flammable objects cannot catch fire. Be absolutely sure to
comply with minimum clearances, in particular to highly com-
bustible objects such as curtains, upholstered furniture, etc.
Please also make sure that the infrared heater can radiate
freely into the room.
ATTENTION:
Strain of any kind on the surface,
whether from persons or objects leaning against it
or from other forces, must be avoided!
C E I L I N G I N S T A L L A T I O N
INSTALLING THE DESIGN INFRARED HEATING:
Please inspect the power supply cord to the heater and the
surface before installation. These must not show any signs of
damage.
1.
Fasten hexagon bolts, spacer discs, and the safety plate
loosely on the rear side of the device. The spacer discs
serve as a means of compensation for the safety plate.
2.
Select a position for the mounting brackets according to
the illustrations on page 14, depending on the product
type.
3.
Drill the holes according to the hole clearances specified
on page 14 et seqq. (for LAVA
drill template supplied can be used).
4.
Screw on the mounting brackets or the retaining hooks us-
ing suitable dowels and screws.
5.
Insert the LAVA
infrared heating on the mounting brack-
®
ets or retaining hooks and tighten the screws.
ATTENTION:
Screws and dowels are not included
in the scope of delivery and must correspond to the
construction material of the ceiling.
12
BASIC-DM 350-1000 W, the
®
NOTE
In case of a ceiling installation, the device must be mounted at
least 1.8 m above the floor.
NOTE
In bathrooms, the device must be mounted so that switches or
other regulators cannot be touched by persons in a bathtub or
shower.
NOTE
Due to the low surface temperature at the rear side (up to
40 °C) the infrared heating may also be mounted on wooden
panelling.
NOTE
The device is not intended for the use in wardrobes and
beneath church benches.
35 mm
Dimensional drawing: minimum mounting clear-
35 mm
35 mm
35 mm
ances