ELECTRICAL CONNECTIONS
Step 2. Motor to Receiver Electrical Connections: (Fig. 14) Connect the black wire from
the fan to the black wire marked "TO MOTOR L" on the receiver. Connect the white
wire from the fan to the white wire marked "TO MOTOR N" on the receiver. Connect
the blue wire from the fan to the blue wire marked "FOR LIGHT" on the receiver.
Secure all the wire connections with the plastic wire nuts provided.
Step 3. (Fig. 14) Receiver to House Supply Wires Electrical Connections: Connect the
black (hot) wire from the ceiling to the black wire marked "AC in L" from the receiver.
Connect the white(neutral) wire from the ceiling to the white wire marked "AC in N"
from the Receiver. Secure the wire connections with the plastic wire nuts provided.
Step 4. (Fig. 14) If your outlet box has a ground wire (green or bare copper) connect it
to the fan ground wires; otherwise connect the hanging bracket ground wire to the
mounting bracket. Secure the wire connection with a plastic nut provided. After
connecting the wires, spread them apart so that the green and white wires are on one
side of the outlet box and black and blue wires are on the other side. Carefully tuck the
wire connections up into the outlet box.
NOTE: Fan must be installed at a maximum distance of 30 feet from the Remote
Transmitter for optimal signal transmission between the transmitter and the fan's
receiving unit.
12 | KICHLER.COM
(CONTINUED)
Outlet box
Black (hot)
Black ("AC IN L")
Receiver
Black ("to motor L")
Blue (for light)
White ("to motor N")
White (neutral)
Black (motor)
Blue (for light)
Fig. 14
White (neutral)
Green or bare
copper (ground)
White ("AC IN N")
Ground to
mounting
bracket or
downrod

Publicité