Suevia 130.8721 Mode D'emploi page 8

Table des Matières

Publicité

Electrical connection
IP54
IP44
230 V
Transformer
24 V
Junction box
10
1
2
Mounting
1. Mount the right and the left side parts of the trough
2. Install cross beams diagonally and screw them tightly
3. Fix the protecting tube
4. Install the tip-over lever and secure it with the screw M6
5. Align the trough and the right and the left side parts, screw them to the wall or the ground
6. Fix the valve body, the lever with the floater, the cover and the angle bracket
> alternatively from the right or the left side of the trough
7. Connect the water supply line ¾"
> water connection can be done alternatively from beneath or from the side (consider DIN 1717 / 1988)
> water pressure max. 5 bar ( 73 psi ).
Flush water line well before you connect the trough!
SUEVIA preliminary filter Ref. 101.0487 should be installed before the trough drinker.
Optional
8. Fix the heating element. Connect it to the electricity means of a transformer (see additional mounting
instructions)
9. Fix the circuit pipe (Ref. 131.0590) for the connection to the water circuit
(see additional mounting instructions)
10. To ensure a frost-free feed pipe, wrap a frost protection heating cable around the pipe. Connect it to the
electricity means of a transformer.
11. The power supply cable, the heating cable and the insulation have to be protected against bites of
animals or damages > fix the biting protection shield for connections from beneath Ref. 131.0579 or
from the side Ref. 131.0580
8
101.0389
°
C
Thermostat
Frost protection heating cable
9
4
1
5
Drainage
hole (on site)
6
101.0487
Water filter
7
Tighten
parts well
5
2
Heating spiral must
be connected to the
¾"
6
8
transformer.
11
3
1
11