ELECTRIC WALL OVEN INSTALLATION INSTRUCTIONS
Flexible Appliance Conduit
Wall Oven Cabinet
Figure 19 - TYPICAL UNDER COUNTER INSTALLATION OF A SINGLE ELECTRIC BUILT-IN OVEN
8. Leveling the Wall Oven
1. Install an oven rack in the center of the oven (see
Figure 20).
2. Place a level on the rack. Take 2 readings with the
level placed diagonally in one direction and then
the other. Use wood shims under the wall oven to
level if necessary.
Figure 20
IMPORTANT NOTE
A cooling fan inside the upper rear part
above the oven (some models) provides
cooling of the oven electrical and electronic
components. If the oven has been operating
at high temperatures, the fan will continue to
run after the oven is turned off.
(and Optional Electric or Gas Cooktop Combination)
Flare
Union
Cabinet sides or
filler panel
WITH A GAS COOKTOP ABOVE
18" (45,7 cm) Max.
5" Max.
6 1/2" Min.
(12,7 cm)
(16, cm)
Flare
Union
9. Checking Operation
Your model is equipped with an Electronic Oven
Control. Each of the functions has been factory
checked before shipping. However, it is suggested that
you verify the operation of the electronic oven controls
once more. Refer to the Use and Care Guide or the
Timer Guide for operation.
1. Remove all items from the inside of the oven.
2. Turn on the power to the oven (Refer to your Use &
Care Guide.)
3. Verify the operation of the electronic oven controls:
Bake– Verify that this function makes the oven hot.
20 seconds after turning oven on, open the door and
you should feel heat coming from the oven.
Broil– When the oven is set to BROIL, the upper
element in the oven should become red.
Convection (some models)–When the oven is set
for a convection baking or roasting, both elements
cycle on and off alternately and the convection fan
will run. The convection fan will stop running when
the oven door is opened.
Before You Call for Service
Read the "Before You Call for Service Checklist" and
the "Operating Instructions" in your Use and Care
Guide. It may save you time and expense. The list
includes common occurrences that are not the result of
defective workmanship or materials in this appliance.
Refer to your Use and Care Guide for service phone
numbers.
10
4" (10 cm)
Right Side
of Cabinet
120V/60Hz
Grounded
(To be
Outlet
accessible
for shut-
Pressure
off valve
Regulator
operation)
Manual
Shutoff
Valve