Remedy Of Faults; Maintenance And Cleaning - Pontec PondoSolar Island 250 Control Notice D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 12
Downloaded from www.watergardeningdirect.com
- EN -

Remedy of faults

Malfunction
Pump does not start.
Insufficient or no pump delivery
LEDs are not lit.
The unit cannot be switched on.

Maintenance and cleaning

The unit has to be taken out of the water for cleaning or maintenance.
Cleaning the unit
 Never use aggressive cleaning agents or chemical solutions. These could attack the housing surface or impair the
function.
 Recommended cleaning agent for removing stubborn limescale deposits:
– Vinegar- and chlorine-free household cleaning agent.
How to proceed:
Disassemble the unit.
Clean the filter housing and impeller unit. (→ Replacing the impeller unit)
Pull the nozzle unit apart.
Clean all parts.
– Use a soft brush as an aid.
– Rinse parts in clean water.
Clean the solar module with a damp cloth and wipe dry.
Reassemble the unit in the reverse order.
10
Cause
No connection to the solar module.
The solar module is soiled.
The impeller unit is blocked.
The battery capacity is exhausted.
Insufficient sunlight
The filter is clogged.
The nozzle unit is clogged.
The impeller unit is worn.
Insufficient sunlight
The battery capacity is exhausted.
No connection to the solar module.
The LED lighting is switched off.
The surrounding area is too light.
The battery capacity is exhausted.
The LED lighting is soiled.
The LED lighting is defective.
The remote control battery capacity is exhausted.
The remote control is too far away from the unit.
No connection to the solar module.
The rechargeable battery is defective.
Remedy
 Check the connection to the solar module.
 Connect the pump to the solar module.
 Push the plug completely into the socket (up
to the stop).
Clean
Clean
Charge the battery for at least 4 hours.
Align the solar module to the sun.
Remove the filter housing, remove and clean
the filter.
Remove and clean the nozzle unit.
Replace
Align the solar module to the sun.
Charge the battery for at least 4 hours.
 Connect the LED lighting to the solar mo-
dule.
 Push the plug completely into the socket (up
to the stop).
Switch on the LED lighting.
Charge the battery for at least 4 hours.
Clean
Dispose of the LED lighting.
Replace
Observe the range of the remote control.
 Check the connection to the solar module.
 Connect the pump to the solar module.
 Push the plug completely into the socket (up
to the stop).
Dispose of the unit.

Publicité

Table des Matières
loading

Table des Matières