Aerus Pure&Dry Mode D'emploi page 8

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

CONTROL PANEL ICONS
1
15
14
DISPLAY SCREEN ICONS:
1. Automatic Mode Icon: Displayed when the
dehumidifier and air purifier run simultaneously.
2. Continuous Dehumidification Mode Icon: Displayed
when the dehumidifier is running continuously.
3. Drying Mode Icon: Displayed when the fan and
dehumidifier are running and using a drainage hose.
4. Safety Lock Icon: Displayed when the Safety Lock is
activated.
5. Air Purification Mode Icon: Displayed when the
louver is activated to regulate air flow distribution.
6. Ventilation Mode Icon: Displayed when the fan is
running continuously, and the dehumidifier is off.
7. Cleaning Mode Icon: Displayed when Cleaning
Mode is activated, operating on high speed to dry
out the inside of the dehumidifier.
8. Air Purifier Filter Detection Icon: Displayed when
the HEPA Filter has been installed, it will display "OK".
When the HEPA Filter is not installed, it will display
"NO".
9. HEPA Filter Timer Icon: The Filter Timer keeps track
of the amount of days the filter has been used.
Replace once per season or every 8 months as
needed.
10. Night Mode Icon: Displayed when Night Mode is
activated and the fan drops to its lowest level.
8
2
3
13
4
5
12
11
10
11. Temperature + Timer Display Icon: Displays the
ambient temperature of the room. During the
Timer Mode, it will display operational time; if you
use the Timer Mode to start the machine, both
Timer and ON will display on the panel; if you use
the Timer Mode to shut off the machine, both
Timer and OFF will display on the panel.
12. Fan Speed + Louver Mode Icon: When operating
low fan speed, the Fan logo will display and
the Waveform logo fluctuation frequency is
0.6 seconds; when operation high fan speed,
the Waveform logo fluctuation frequency is 0.2
seconds. When the Louver Mode has started, the
display icon will swing back and forth and the
frequency is 0.5 seconds. When the Louvre Mode
has been turned off, the middle three lines will not
be displayed; the running display will be displayed
and the Fan Speed icon will represent fan speed.
13. Humidity Level Icon: Displays the humidity of your
environment; if you set the humidity, it will display
your chosen humidity setting.
14. Low Temperature Alert Icon: When room
temperature is less than 50
icon will light up. When the room temperature is
less than 35
F the Low Temperature icon will flash.
º
It is recommended to turn the machine off below
40
F.
º
15. Full Bucket Alert Icon: When the water collection
bucket is full, this icon will flash on the display and
the unit will beep for 10 seconds. Empty the water
from the bucket and place the bucket back into
position.
6
7
9
F the Low Temperature
º
8