Radio Frequency Communication - Gewiss GW 10 841 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

OPERATING INSTRUCTIONS

Radio frequency communication

CONFIGURATION
To make the association with an output module press keys
and
simultaneously,
after having set the output module in learn configuration (see the relative instruction sheet).
The actual transmission of a command is signaled on the display by the temporary swit-
ching on of symbol
, RF transmission.
OPERATION
The timer-thermostat operates in combination with a 3A or 16A output module in BISTABLE
operating mode, sending switch on/switch off commands depending on its temperature
regulation mode and the type of operation selected (heating or air conditioning).
The timer-thermostat periodically retransmits the command, every 5 minutes, to the
ombined actuator. If the actuator does not receive the message for 4 consecutive times, it
commands opening of the relay (OFF) and signals the fault with the green LED blinking.
SIGNALS
Transmission of a command
The transmission of an RF command (ON/OFF) is signaled on the display by the temporary
switching on of symbol
.
34

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Gw 14 841Chorus gw 10 701Chorus gw 14 701

Table des Matières