GYS WCU 0.5KW A Mode D'emploi page 10

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 1
3
Connect the two connection cables from the cooling unit and place
the excess cable length in the cooling unit.
4
Refix the 4 screws through the frame of the cooling unit
COOLING LIQUID
The operator must fill the tank up to its maximum indicated on the front of the cooling unit but never under the minimum line or a warning message
will be displayed on the screen. The CORAGARD CS330 cooling liquid (or equivalent), recommended by the manufacturer, must be used (more infor-
mation on the website: http://www.aqua-concept-gmbh.eu). The use of any other coolant, and including the special automotive one, can lead, by
electrolysis effect, to the accumulation of dumps in the cooling system, damaging it and even more by blocking the circuit.
The maximum level indication is essential to optimize the duty cycle of the machine.
Any damage caused to the machine by the use of another cooling liquid will not be taken under warranty.
The recommended cooling system unit is automatically detected by the machine. In the OPTION menu, this cooling unit system can be deactivated.
Make sure that the cooling unit is turned off before disconnecting the inlet and outlet hoses for torch liquid.
The coolant is harmful and irritates the eyes, the mucus membranes and the skin. Hot liquid may cause burns.
TROUBLESHOOTING
This device integrates a default management system. This allows the operator to diagnose the errors and anomalies with the help of the instruction
manual (Troubleshooting chapter).
10
WCU0.5KWA / WCU1KW A/B
(back and rear).
Connect the two connection cables from the cooling unit and place
the excess cable length in the cooling unit.
Refix the 6 screws through the frame of the cooling unit
(on the sides).
EN

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Wcu 1kw aWcu 1kw b

Table des Matières