1.0 INTRODUCTION
1.1 Kit Contents
ALL kit contents must be installed.
•
(2) 15" plenum kit: #KZK-1510A
•
(2) air grilles
•
(8) 6" collars - (4) to attach to the bottom of the plenum; (4) to
attach to the unit where the cover plates are removed.
(1) KZK-410-6 is used for a 10' vent run. If you are mounting the
plenum above the fireplace 10' (3m) or less, use (1) #KZK-410-6 kit.
KZK-CPL6 is (6) 6" couplers that connect (2) KZK-410-6. You will only
need (4) 6" couplers for installation. If you are mounting the plenum
above the fireplace between 10' to 20' , you will need (2) KZK-410-6 kit
and (1) #KZK-CPL6 coupler kit.
#KZK-1510A
(4) take o collars included
Figure 1.1, #KZK-1510A
#KZK-410-6
(4) - 10' x 6" (aluminum ex) listed to UL-181Class 0 Air Duct
Figure 1.2, #KZK-410-6
Komfort Zone Kit #KZK-1510A R.4
1.2 Fireplace Preparation
1.2.1 BHM-44 Requirements
For ease of installation, the header heat shield may be removed.
The stand-off assembly still must be installed. To install stand-off
assembly,
1.
Locate the stand-off assembly and header heat shield on top of
the fireplace, as shipped.
2.
Discard header heat shield.
3.
Attach the stand-off assembly pieces as shown below and secure
with (4) screws.
¾"
15
(400mm)
¾
11
"
(298mm)
Figure 1.3, Stand-off Assembly Installation
Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces
Discard header heat shield
Stand-o
assembly
INTRODUCTION 3