Kozy Heat Fireplaces KZK-1510A Manuel D'installation

Komfort zone kit for use with the bhm-44 and clw-50
Masquer les pouces Voir aussi pour KZK-1510A:

Publicité

Les langues disponibles

Les langues disponibles

Liens rapides

KOMFORT ZONE KIT
#KZK-1510A
For use with the #BHM-44 and #CLW-50
Serial Number: 19 501780 50)
English and French installation manuals are available through your
local dealer. Visit our website www.kozyheat.com.
Les manuels d'installation en français et en anglais sont disponibles
chez votre détaillant local. Visitez www.kozyheat.com .
1.0 INTRODUCTION .......................................................................3
1.1 Kit Contents.......................................................................................... 3
1.4 Fireplace Preparation ........................................................................ 3
1.2 Suggested Configurations .............................................................. 4
1.3 Dimensions and Overview ............................................................. 6
1.5 Air Duct Pipe Run ............................................................................... 8
2.0 FRAMING AND CLEARANCES ................................................9
2.1 Clearance to Sprinkler ...................................................................... 9
2.2 Framing................................................................................................10
2.3 Shelf Requirements .........................................................................12
3.0 FACING AND FINISHING .......................................................14
3.1 Non-combustible Requirements ................................................14
3.2 Combustible Finish ..........................................................................16
3.3 Hearth and Mantel Clearances ....................................................19
4.0 INSTALLATION .......................................................................21
Hussong Manufacturing Co., Inc.
P.O. Box 577, 204 Industrial Park Drive
Lakefield, MN 56150-0577, USA
(Starting
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
HUSSONG MANUFACTURING CO., INC.
READ ALL THESE STEPS
BEFORE STARTING INSTALLATION.
LEAVE THESE INSTRUCTIONS WITH THE
APPLIANCE.
This kit must be installed by a qualified installer,
service agency, or gas supplier at the time of
the heater installation. These instructions must
be used in conjunction with the installation and
operation manual provided with the appliance.
Please read the appliance owner's manual
completely before performing any procedures in
these instructions.
This optional convection duct kit redistributes the
warm air flow away from the fireplace opening to
a more desirable location using natural convection
without the use of a fan. The warm air flow may be
relocated to a position higher up the wall, out the
sidewalls, or even to an adjacent room. The result
is much cooler wall temperatures above the fire-
place opening for locating televisions, artwork, etc.
Rev. 4, 8/20

Publicité

Chapitres

Table des Matières
loading

Sommaire des Matières pour Kozy Heat Fireplaces KZK-1510A

  • Page 1: Table Des Matières

    KOMFORT ZONE KIT #KZK-1510A For use with the #BHM-44 and #CLW-50 (Starting HUSSONG MANUFACTURING CO., INC. Serial Number: 19 501780 50) INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference. English and French installation manuals are available through your READ ALL THESE STEPS local dealer.
  • Page 3: Introduction

    Figure 1.1, #KZK-1510A #KZK-410-6 Figure 1.3, Stand-off Assembly Installation (4) - 10’ x 6” (aluminum ex) listed to UL-181Class 0 Air Duct Figure 1.2, #KZK-410-6 Komfort Zone Kit #KZK-1510A R.4 Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces INTRODUCTION 3...
  • Page 4: Suggested Configurations

    1.3 Suggested Configurations When installing the #KZK-1510A, take in consideration the fireplace venting and the plenum tube configuration. The (2) plenums and the (2) air grilles in this kit are required and both must be installed. CLW-50 #KZK-1510A rear wall outlet #KZK-1510A side wall outlet Figure 1.4, #KZK-1510A Suggested Configurations for CLW-50...
  • Page 5 For side wall outlet installations, it is easier to keep the 1/2” (12mm) clearance if the center tubes are assembled to the backside of the KZK Figure 1.5, #KZK-1510A Suggested Configurations for BHM-44 Komfort Zone Kit #KZK-1510A R.4 Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces...
  • Page 6 (342mm) stando 3” (38mm) (76mm) ⁄ ” ⁄ (149mm) ” (220mm) ¾ stando (19mm) ⁄ ” 4” 6” (198mm) (102mm) (152mm) Figure 1.6, #KZK-1510A Dimensions 6 INTRODUCTION Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces Komfort Zone Kit #KZK-1510A R.4...
  • Page 7: Air Duct Pipe Run

    Minimum bend radius=5” (127mm) 4” (102mm) 4” (102mm) 12” 12” (304mm) (304mm) BHM-44 CLW-50 Figure 1.7, Minimum Vent Pipe Run - only (1) plenum shown Komfort Zone Kit #KZK-1510A R.4 Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces INTRODUCTION 7...
  • Page 8: Framing And Clearances

    ½ ” Ceiling (89mm) MIN sprinkler head BHM-44 60” (1524mm) MIN 3” Ceiling (76mm) MIN sprinkler head Figure 2.1, KZK Clearance to Sprinkler 8 FRAMING AND CLEARANCES Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces Komfort Zone Kit #KZK-1510A R.4...
  • Page 9: Framing

    (38mm) ½ ½ ½ ½ ” ” ” ” (12mm) (12mm) (12mm) (12mm) Figure 2.2, Minimum Clearances for Plenum Air Discharge to Ceiling Komfort Zone Kit #KZK-1510A R.4 Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces FRAMING AND CLEARANCES 9...
  • Page 10 (1638mm) ½ ” (1130mm) 22” 76” (559mm) ½ ” (1930mm) (1638mm) ½ ” 22” (1130mm) (559mm) Figure 2.4,CLW-50 Unit Wall Enclosure Rough Opening 10 FRAMING AND CLEARANCES Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces Komfort Zone Kit #KZK-1510A R.4...
  • Page 11 88” (2235mm) 88” ⁄ ” (2235mm) ¼ ” (1463mm) (1175mm) 22” ¼ ” (558mm) (1175mm) Figure 2.6, BHM-44 Unit Wall Enclosure Rough Opening Komfort Zone Kit #KZK-1510A R.4 Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces FRAMING AND CLEARANCES 11...
  • Page 12: Shelf Requirements

    76” 22” (1930mm) (559mm) Grille 3” (76mm) ¾ 76” ” 18” (1930mm) (2102mm) (457mm) Enclosure Floor Enclosure Floor Figure 2.7, CLW-50 Shelf Requirements 12 FRAMING AND CLEARANCES Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces Komfort Zone Kit #KZK-1510A R.4...
  • Page 13 22” (406mm) (559mm) 88” (2235mm) 0” (0mm) 18” Grille (457mm) 16” (406mm) 88” (2235mm) Enclosure Floor Enclosure Floor Figure 2.8, BHM-44 Shelf Requirements Komfort Zone Kit #KZK-1510A R.4 Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces FRAMING AND CLEARANCES 13...
  • Page 14: Facing And Finishing

    No Screws Allowed No Screws Allowed ¾ 13” ¾ ” 13” ” (330mm) (95mm) (330mm) (95mm) Figure 3.2, Minimum Non-combustible Finishing Dimensions Screw Locations 14 FACING AND FINISHING Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces Komfort Zone Kit #KZK-1510A R.4...
  • Page 15 (1148mm) ⁄ ” (633mm) ½ ” (1130mm) ½ ” (63mm) Non-combustible material only Combustible material allowed Figure 3.3, BHM-44 Minimum Non-combustible Finishing Dimensions Komfort Zone Kit #KZK-1510A R.4 Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces FACING AND FINISHING 15...
  • Page 16: Combustible Finish

    (301mm) ⁄ ” (301mm) NOT ALLOWED INSIDE MINIMUM SHELF ENCLOSURE Figure 3.4, #KZK-1510A Drywall Finish and Combustible Finishing Material up to 1" Thick 16 FACING AND FINISHING Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces Komfort Zone Kit #KZK-1510A R.4...
  • Page 17 Steel may be installed over Framing cement board Non-combustible material Finishing Edge Fireplace Enclosure Floor Figure 3.5, #KZK-1510A Combustible Wall Finish for CLW-50 Komfort Zone Kit #KZK-1510A R.4 Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces FACING AND FINISHING 17...
  • Page 18 Non-combustible material Top nishing edge Figure 3.6, #KZK-1510A Combustible Wall Finish for BHM-44 18 FACING AND FINISHING Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces Komfort Zone Kit #KZK-1510A R.4...
  • Page 19: Hearth And Mantel Clearances

    Finishing Edge 6” (152mm) ¾ 9” (229mm) ” (248mm) 12” (305mm) Fireplace Enclosure Floor Figure 3.8, Hearth and Mantel Clearances for No Surround Komfort Zone Kit #KZK-1510A R.4 Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces FACING AND FINISHING 19...
  • Page 20 Top nishing edge 25” (635mm) ½ ” (699mm) ½ ” Bottom (64mm) nishing edge 14” (356mm) Combustible oor Figure 3.9, BHM-44 Hearth and Mantel Clearances 20 FACING AND FINISHING Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces Komfort Zone Kit #KZK-1510A R.4...
  • Page 21: Installation

    Instructions continue on the next page. Figure 4.4, BHM-44 vConvection Baffle Removal Komfort Zone Kit #KZK-1510A R.4 Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces INSTALLATION 21...
  • Page 22 Use metal strapping (not supplied) as required to further secure the plenum to framing. Attach the piping from all (4) plenum take off collars to all (4) take off collars on the fireplace. If you are mounting the plenum 10' or less above the fireplace, use (1) #KZK-410-6 kit or UL-181 Class 0 approved air duct.
  • Page 23 KIT KOMFORT ZONE nº KZK-1510A Pour utiliser avec le foyer au gaz à évacuation HUSSONG MANUFACTURING CO., INC. directe nº BHM-44 et nº CLW-50 ( Début du numéro de série : 19 501780 50) INSTALLATEUR : Laissez ce manuel avec l’appareil.
  • Page 25: Introduction

    1.2 Préparation du foyer Toutes les composants de ce kit est requis et doit être installé. 1.2.1 BHM-44 • (2) plénum de 15 po du kit KZK-1510A L'écran thermique du linteau n'est pas requis pour cette installation. • (2) grilles d'air Les étriers de dégagement doivent être installés.
  • Page 26: Configurations Suggérées

    1.3 Configurations suggérées CLW-50 #KZK-1510A sortie murale arrière #KZK-1510A sortie murale adjacent Figure 1.4, CLW-50 Configurations suggérées du KZK-1510A 4 INTRODUCTION Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces Kit Komfort Zone nº KZK-1510A R.4...
  • Page 27 C’est plus facile de maintenir le dégagement de 1/2 po autour conduits pour l'installations sortie murale arrière si les conduits centraux sont assemblés à l'arrière de KZK Figure 1.5, BHM-44 Configurations suggérées du KZK-1510A Kit Komfort Zone nº KZK-1510A R.4 Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces...
  • Page 28: Dimensions Et Vue D'ensemble

    (76mm) ⁄ ” ⁄ (149mm) ” (220mm) ¾ (19mm) espaceur de dégagement ⁄ ” 4” 6” (198mm) (102mm) (152mm) Figure 1.6, Dimensions du KZK-1510A 6 INTRODUCTION Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces Kit Komfort Zone nº KZK-1510A R.4...
  • Page 29: Installation Des Conduit D'air

    Rayon de courbure minimal = 5” (127mm) 4” (102mm) 4” (102mm) 12” 12” (304mm) (304mm) BHM-44 CLW-50 Figure 1.7, Installation de conduits d'air de longueur minimale Kit Komfort Zone nº KZK-1510A R.4 Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces INTRODUCTION 7...
  • Page 30: Encadrement Et Dégagements

    BHM-44 60” (1524mm) MIN 3” Tête de gicleur (76mm) MIN au plafond Figure 2.1, Dégagement au gicleur du kit KZK 8 ENCADREMENT ET DÉGAGEMENTS Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces Kit Komfort Zone nº KZK-1510A R.4...
  • Page 31: Encadrement

    ½ ½ ½ ½ ” ” ” ” (12mm) (12mm) (12mm) (12mm) Figure 2.2, Dégagement minimal de la sortie d'air au plafond Kit Komfort Zone nº KZK-1510A R.4 Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces ENCADREMENT ET DÉGAGEMENTS 9...
  • Page 32 (1219mm) (1638mm) ½ ” (1130mm) 22” 76” (559mm) ½ ” (1930mm) (1638mm) ½ ” 22” (1130mm) (559mm) Figure 2.4, Encadrement et dégagement 10 ENCADREMENT ET DÉGAGEMENTS Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces Kit Komfort Zone nº KZK-1510A R.4...
  • Page 33 ” (108mm) 88” (2235mm) 88” ⁄ ” (2235mm) ¼ ” (1463mm) (1175mm) 22” ¼ ” (558mm) (1175mm) Figure 2.6, Encadrement et dégagement Kit Komfort Zone nº KZK-1510A R.4 Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces ENCADREMENT ET DÉGAGEMENTS 11...
  • Page 34: Dimensions D'installation Et Exigences Avec Étagère

    3” (76mm) ¾ 76” ” 18” (1930mm) (2102mm) (457mm) Plancher de l’enceinte Plancher de l’enceinte Figure 2.7, CLW-50 Requis d'une tablette d'étagère 12 ENCADREMENT ET DÉGAGEMENTS Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces Kit Komfort Zone nº KZK-1510A R.4...
  • Page 35 0” (0mm) 18” Grille (457mm) d’air 16” (406mm) 88” (2235mm) Plancher de l’enceinte Plancher de l’enceinte Figure 2.8, BHM-44 Requis d'une tablette d'étagère Kit Komfort Zone nº KZK-1510A R.4 Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces ENCADREMENT ET DÉGAGEMENTS 13...
  • Page 36: Façade Et Finition

    ¾ ” 13” ” (330mm) (95mm) (330mm) (95mm) Figure 3.2, Emplacements de vis permis (pour matériaux incombustibles de finition de dimensions minimales 14 FAÇADE ET FINITION Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces Kit Komfort Zone nº KZK-1510A R.4...
  • Page 37 (633mm) ½ ” (1130mm) ½ ” (63mm) Matériaux incombustibles Matériaux combustible seulement permis Figure 3.3, Dimensions minimales des matériaux incombustibles de finition Kit Komfort Zone nº KZK-1510A R.4 Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces FAÇADE ET FINITION 15...
  • Page 38: Matériaux De Finition Combustibles

    Cette installation n'est pas autorisée pour une tablette encastrée Figure 3.4, Revêtement en matêriau combustible et Matériaux de finition combustibles de 1 po d'épaisseur maximale 16 FAÇADE ET FINITION Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces Kit Komfort Zone nº KZK-1510A R.4...
  • Page 39: Clw-50 Matériaux De Finition Murale Combustibles

    Bord de nition du foyer Plancher d’enceinte du foyer Figure 3.5, Matériaux de finition murale combustibles avec le KZK-1510A Kit Komfort Zone nº KZK-1510A R.4 Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces FAÇADE ET FINITION 17...
  • Page 40: Bhm-44 Matériaux De Finition Murale Combustibles

    être installée par dessus le panneau de ciment Matériau incombustible Bord de nition du foyer Figure 3.6, Matériaux de finition murale combustibles 18 FAÇADE ET FINITION Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces Kit Komfort Zone nº KZK-1510A R.4...
  • Page 41: Dégagements De L'âtre Et Du Manteau

    9” (229mm) ” (248mm) 12” (305mm) Plancher d’enceinte du foyer Figure 3.8, Dégagements de l’âtre et du manteau pour une installation sans contour Kit Komfort Zone nº KZK-1510A R.4 Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces FAÇADE ET FINITION 19...
  • Page 42: Bhm-44 Dégagements De L'âtre Et Du Manteau

    Bord de ntion (64mm) du foyer 14” (356mm) Plancher combustible Figure 3.9, Dégagements de l’âtre et du manteau pour une installation sans contour 20 FAÇADE ET FINITION Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces Kit Komfort Zone nº KZK-1510A R.4...
  • Page 43: Installation

    Figure 4.4, BHM-44 Déflecteur de convection retiré Installez le(s) plénum(s) dans l’ouverture brute encadrée, tout en maintenant les dégagements minimums aux matériaux combustibles, tels que spécifiés aux pages précédentes. Fixez Kit Komfort Zone nº KZK-1510A R.4 Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces INSTALLATION 21...
  • Page 44 le plénum à l’encadrement, avec des vis (ou clous) traversant la bride de fixation supérieure. Utilisez des bandes d’attache métalliques de type AllRound(R) (non fournies) comme support additionnel pour fixer solidement le plénum à l’encadrement. Raccordez les conduits, partant des (4) collets de fixation du plénum jusqu’aux (4) collets de fixation du foyer.